Important:
Do not remove clear plastic covering film on ceramic glass until cook top is
ready to install.
PLEASE RECORD YOUR COOK TOP SERIAL # HERE FOR FUTURE REFERENCE:
Step #2- Check Your Electrical Supply Requirements:
This product must be installed in accordance with national electric codes, as well as state and
local codes. The following table provides the correct voltage, amperage, and frequency that
must be supplied to the appliance.
Kenyon Part #
Model
Max
Connected
Load
Required Power
Supply Input
Minimum
Wire Size
B43001
4BTC-Car
5800 Watts
240 VAC/30A/60 Hz
#10 AWG
B44001
4BTC-Med
5800 Watts
240 VAC/30A/60 Hz
#10 AWG
The supply must be from an individual grounded circuit that is protected by a circuit breaker
rated per the specifications for the various models as shown in the table above.
Warning:
If the electric power supply provided does not meet the product
specifications, call a licensed electrician before proceeding with installation.
!
Step #3- Power Disconnection:
Disconnect power to the appliance by opening the circuit breaker before proceeding any further
with installation. Failure to disconnect power supply may result in electrical shock or fire
hazard.
3