- 7 -
PLASMA 100 Operating Manual
2.0 INSTALLATION RECOMMENDATION
Installation Environment
PLASMA 100 is designed for use in hazardous environments.
Examples of environments with increased hazardous environments are -
In locations in which freedom of movement is restricted, so that the operator is forced to perform the work
in a cramped (kneeling, sitting or lying) position with physical contact with conductive parts; In locations which
are fully or partially limited by conductive elements, and in which there is a high risk of unavoidable or
accidental contact by the operator, or in wet or damp hot locations where humidity or perspiration
considerable reduces the skin resistance of the human body and the insulation properties of accessories.
Environments with hazardous environments do not include places where electrically conductive parts in
the near vicinity of the operator, which can cause increased hazard, have been insulated.
Installation Location
Be sure to locate the cutter according to the following guidelines:
z
In areas, free from moisture and dust.
z
In areas, not subjected to abnormal vibration or
shock.
z
In areas, free from oil, steam and corrosive
gases.
z
Place at a distance of 304.79mm or more from
walls or similar that could restrict natural airflow
for cooling.
z
In areas, not exposed to direct sunlight or rain.
z
Ambient
temperature: between -10 degrees C
to 40 degrees C.
WARNING 1
KENZO advises that this equipment be electrically connected by a qualified electrician.
The following Primary Current recommendations are required to obtain the maximum cutting current and duty
cycle from this Power Supply:
Model
Primary supply
lead size
Minimum primary
current circuit size
Duty cycle
PLASMA 100
Minimum 4.0mm
2
380V/26.3A
415V/24.1A
100A/120V@100%
Table 1 Primary current circuit sizes to achieve maximum current