Set Style
Parameters
Description
Step down
Low limit
High limit
Break time
This Attribute becomes active
automatically when the window is
active. The Value is decremented
at regular intervals as specified by
the
Break time
until the
Low
limit
is reached. Then the Value is
reset to the
High limit
. This cycle
is repeated until the window
becomes inactive.
Set at
window
maximized
Set value
Set value
data is written to the
designated word automatically
when the window containing it is
maximized.
Set at
window
minimized
Set value
Set value
data is written to the
designated word automatically
when the window containing it is
minimized.
Set at
backlight
off
Set value
Set value
data is written to the
designated word automatically
when the backlight is turned off.
Design Tip:
Use the following to provide error codes to the
PLC after data entry.
Set at
enter
success
Set value
When a function key with the
ENT attribute is pressed in
response to a Numeric Input or
ASCII Input part and the attempt
to write the data succeeds, the
designated Device Address is
loaded with the
Set value
.
Set at
enter fail
Set value
When a function key with the
ENT attribute is pressed in
response to a Numeric Input or
ASCII Input part and the attempt
to write the data fails, the
designated Device Address is
loaded with the
Set value
.