13.14 Indirect Window
The Indirect Window places a defined child window area over the current window. The Indirect Window’s screens
are created the same as regular base windows. Usually their size is smaller than a full window. The Windows are
then displayed in the Indirect Window frame as called by a PLC data register. The limitation to the maximum
registered Indirect Windows on each screen is 500. However, at run time, only 5 windows at the most can be displayed
simultaneously on each screen.
Note:
Only valid window numbers are displayed. If the window number is not defined then the Indirect Window area is left
transparent.
Note:
Indirect Windows disable Popup function keys placed on the same screen. A popup window can only be triggered
by one method on any given window.
Screen 10
Register an Indirect Window with
“Read Address = D100”
Screen 10
Screen 21 is displayed
Word
Value
D100
21
Screen 10
Word
Value
D100
20
Screen 20 is displayed.
While active, D100 designates the
pop up window