16.16.4 Device address
Bit/Word
Type
Address Format
Range
Notes
B
End_Command
d
d: 0
The End_Command is used to suspend or enable
communications to the PLC. Communications are
automatically started when the HMI is powered up.
B
Relay(bit)
dddbb0
dddbb:0~19999
bb: 00~15
Must add “0” after the address
W
DM
dddd
dddd: 0~1999 Data Memory
W
TM
dd
dd: 0~99
Temporary Memory
W
Relay
ddddd
ddd: 0~19999 Relays
W
Timer_Contact
ddd
ddd: 0~999
Timer Bits
W
Timer_Current
ddd
ddd: 0~999
Timer Accumulator
W
Timer_Preset
ddd
ddd: 0~999
Timer Preset
W
Counter_Contact
ddd
ddd: 0~999
Counter Bits
W
Counter_Current
ddd
ddd: 0~999
Counter Accumulator
W
Counter_Preset
ddd
ddd: 0~999
Counter Preset
The PLC’s memory range may vary within the range supported by the driver. Use appropriate addresses.