269
16.30.3.15
Wiring for cable connections using
984 Series, Compact, Control Microsystems SCADAPack
Series, Emerson E-Series, SAF Drives, TSX Quantum and other MODBUS Compatible CPU’s
with RS-485 D-Sub 9 Male Socket ports.
KEP Part#: (Not Available) (D-Sub 9 Female Plug to D-Sub 9 Female Plug Cable)
HMI PLC[RS-485]
MODBUS COMPATIBLE CPU RS-485 port
1 RXD
Æ
9 RD
2 RXD
Æ
4 TD
5 GND
Æ
5 GND
1 Shield
Shield
Æ
Earth Ground
16.30.3.16
Wiring for cable connections using
Entertron, TSX Nano, TSX Twido
,
Industrial Control Links
ICL Series, Watlow Anafaze CAS200, CLS200, Series Controllers
with RS485 screw terminal
ports.
KEP Part#: (Not Available) (D-Sub 9 Female Plug to Flying Leads Cable)
HMI PLC[RS-485]
Entertron, TSX Nano or Industrial Control Links ICL Series or Watlow Anafaze
CAS200, CLS200, Series CPU’s with RS485 Port
1 RXD-
Æ
3 TXD-
Æ
Æ
1 RXD-
2 RXD+
Æ
4 TXD+
Æ
Æ
2 RXD+
5 GND
Æ
Æ
3 GND
Shield
Æ
Earth Ground
16.30.3.17
Wiring for cable connections using
International Parallel Machines Controllers
with D-Sub 9
Female Plug ports.
KEP Part#: (Not Available) (D-Sub 9 Female Plug to D-Sub 9 Male Socket Cable)
HMI PLC[RS-485]
International Parallel Machines Controllers
with RS485 Port
1 RXD-
Æ
9 DO-
2 RXD+
Æ
8 DO+
3 TXD-
Æ
5 DI-
4 TXD+
Æ
4 DI+
5 GND
Æ
1 GND
Shield
Æ
Earth Ground