Common Window:
Window 6 is the default common window. Objects placed on a common window are always displayed
and active. The following settings determine how they appear.
Popup window
: Determines where an indirect or direct popup window called from the common window is displayed.
Normal:
The Popup window is displayed on the layer above the parent-calling window. If another
window is on top of the calling window, it may hide the popup.
Above any others:
The popup window is displayed on the top layer when activated.
Attribute
: Determines the location of the Common window.
Below base screen:
The common window is always on the bottom layer of the display. All windows
cover the common window.
Above base screen:
The common window is always in the top layer. All windows are below the
common window. Controls and objects on the Common window are always visible.
Extra No. of Event:
Normally, 200 events are stored in the Event Log. If more than 200 events are needed, the additional
amount is entered here. Up to 2800 additional logs can be added. For example, if 1000 events need to be logged, enter 800
in this field. See the
Event Log
part for details on the Event Logger.
RTC Source
: The RTC Source determines where the Event Log part and Printer obtains the real time information for their
display and printout.
Local Word:
Uses the values in
LW 9010
to
LW9016
. The RTC data from your PLC must be
transferred to
LW9010
to
LW9016
before use. This is done with a
Data Transfer
part.
Note:
All values must be BCD coded.
LW Address
Description
Valid Values
9010
Real Time Clock second.
0 - 59
9011
Real Time Clock minute.
0-59
9012
Real Time Clock hour.
0-23
9013
Real Time Clock day.
0-31
9014
Real Time Clock month.
0-11
9015
Real Time Clock year.
0-9999
9016
Real Time Clock day of the week.
0-6
Internal RTC:
Uses the RTC in the HMI (
RW60000
to
RW60006
). All values are BCD coded.
RW Address
Description
Valid Values
60000
Real Time Clock second. (read and write allowed)
0 - 59
60001
Real Time Clock minute. (read and write allowed)
0-59
60002
Real Time Clock hour. (read and write allowed)
0-23
60003
Real Time Clock day. (read and write allowed)
0-31
60004
Real Time Clock month. (read and write allowed)
0-11
60005
Real Time Clock year. (read and write allowed)
0-9999
60006
Real Time Clock day of the week. (read and write allowed)
0-6