36
Print:
Use these settings to set the Printer protocol. This enables Function Key Screen and Event printing as well as the
display of printer errors. Time format for Event printing is also set here.
Printer:
Select the printer protocol.
None:
Printing disabled.
EPSON ESC/P2:
Typically used with dot matrix line printers.
SP Printer:
Simple printing used with ASCII type printers.
HP PCL/Simple Page Mode:
Use with PCL compatible laser printers.
Note:
Local Bit, LB 9017, is the control bit for printing. If LB9017 is set OFF/ON, printing is disabled/enabled.
Note:
If
None
is selected, all print functions and LB9017 are disabled.
Print time tag:
Print the time in Hours:Minutes:Seconds format along with the printed information.
Print date tag:
Print the Date in Month:Day format along with the printed information.
Print Sequence number:
Select to print the sequence number of the event along with the event occurrence.
Extended time format (D:H:/M):
Change the time format in the time tag to Days/Hours/Minutes.
Extended date format (Y/M/D):
Change the time format in the time tag to Year/Month/Day.
Error Detection:
Select how printer errors are handled.
Local Bit LB 9016 is used for internal error reporting.
Setting
Description
No error detection
Printer errors are ignored.
Error detection (show message)
A message box pops up on the HMI display when printer errors occur.
Error detection (set local bit)
LB 9016 is set to 1 when printer errors occur.
LB 9016 remains high until reset by
some user action. It is up to the programmer to handle this error by popping up a
window or providing a way to reset the bit.
Message board window No. (0,10~1999):
The message board allows the operator to draw a message within the
designated window, using the touchscreen. This is especially useful when the operator needs to leave a note about machine
status or the operator’s whereabouts when not at the machine. The operator can simply write “MACHINE DOWN” or
“Lavatory”. Or, some process note or calculation can be entered as a reminder; such as “Ba.005”. The message
window retains its data until power is lost. This allows the message window to be closed and then opened later without loss
of information.
Select the window number to be used as the message board.
Note:
Selecting 0 disables the Message board feature.
Note:
Only one Message board window per project is allowed.
Note:
See the
Function Key
part section for information about Message board controls.
Note:
Some of the project’s
System Parameter/General Tab
settings are stored in the retentive memory. See the
System
Bit and Register Reference
section for further details.