38
7.2.4 The Security Tab
The
Security
tab is used for setting security levels and access codes.
Note:
Reference the
Security
section for further details on Security Control.
Security Control
This check box activates the
security feature. Security levels are assigned to
windows in their Window Settings dialog. There
are three levels of security.
Lowest - Level 0
is the lowest level of security.
Middle - Level 1
allows access to Level 1 and
Level 0 windows.
Highest - Level 2
is the highest level of security
and can access all levels.
Each level’s password is a double word value (0
to 99999999). Passwords are numeric digits
only and cannot contain any alphabet
characters.
Note:
A password of 0 for a Security level
disables security for that level (all users can
access that level).
Note:
The project’s Security level settings are
stored in the retentive memory of the MMI. See
the
System Bit and Register Reference
section for further details.