3-54
BHK-MG (OPR) 032816
NOTE: If using two different BHK models, e.g., 500-0.4MG and 1000-0.2MG, unit A must be
the one with the lower current capacity: 1000-0.2MG
a. Program IsetA to the current limit for the power assembly.
b. Program VsetA to:
(to nearest volt) where:
• Eo is the output voltage of the power assembly,
• EomaxA is the rated maximum output voltage for unit A (e.g. 500 for the BHK 500-
0.4MG),
• EomaxB is the rated maximum output voltage for unit B.
c. Program overcurrent value of unit A (IocsetA) to 1.1 x current limit for power assembly
(step 3a).
d. Program overvoltage value of unit A (VovsetA) to 1.1 x VsetA (step 3b).
4. Program unit B as follows:.
a. Program IsetB to approximately 1.01 to 1.02 x IsetA (step 3a). This maximum current
limit is never used except in the unlikely event that the current limit of Unit A is not work-
ing.
b. Program VsetB to (Eo – VsetA) (VsetA is set in step 3b).
c. Program overcurrent value of unit B (IocsetB) to 1.1 x IsetB (step 4a).
d. Program overvoltage value of unit B (VovsetB) to 1.1 x VsetB (step 4b).
5. To apply power to the load:
a. If load switch used, close the switch.
b. If load switch not used, press POWER ON/OFF key (once) on unit B, then unit A.
6. To disable power to the load:
a. If load switch used, open the switch.
b. If load switch not used, press POWER ON/OFF key once: first on unit A, then on unit B.
c. Alternative: Turn both units off by setting POWER switch to off (down) position, first on
unit A, then on unit B.
V s e t
E o
E o m a x A
E o m a x A
E o m a x B
+
----------------------------------------------------------------
=
Summary of Contents for BHK 1000-0.2MG
Page 2: ......
Page 6: ......
Page 17: ...BHK MG032816 xi FIGURE 1 1 BHK MG SERIES PROGRAMMABLE POWER SUPPLY ...
Page 18: ...xii BHK MG032816 ...
Page 46: ......
Page 101: ...BHK MG OPR 032816 3 55 FIGURE 3 20 SERIES AUTOMATIC CONFIGURATION ...
Page 109: ...BHK MG OPR 032816 3 63 FIGURE 3 23 PARALLEL AUTOMATIC CONFIGURATION ...
Page 114: ...3 68 BHK MG OPR 032816 FIGURE 3 25 PARALLEL MASTER SLAVE CURRENT MODE CONFIGURATION ...
Page 116: ......
Page 154: ......