BHK-MG (OPR) 032816
3-67
b. If load switch not used, press POWER ON/OFF key once on slave unit, then once on
master unit.
6. To disable power to the load:
a. If load switch used, open the switch.
b. If load switch not used, press POWER ON/OFF key once on master unit, then once on
slave unit.
c. Alternative: Turn both units off by setting POWER switch to off (down) position, first on
master unit, then on slave unit.
3.7.3.2.2 CURRENT MODE OPERATION
When the parallel combination is configured to operate in current mode (see Figure 3-25), the
master is in current mode, receiving current programming commands, and the slave tracks the
output current of the master.
The output current of the assembly in current mode is given by the equation,
Io = 2 x Io
M
, where Io
M
is the output current of the master, in mA.
The load voltage is given by
Eo = 2 x Io
M
x R
LOAD
.
NOTES: 1. The uncommitted amplifier of the slave unit uses 0.0091 mA (maximum) of the out-
put current, reducing the accuracy of the generated current. This can be avoided by
using the uncommitted amplifier of the master unit, configured as a non-inverting
repeater, between the signal coming from the master sensing resistor signal (termi-
nal 2) and the input to R1 shown in Figure 3-25.
2. The current of the slave unit will be slightly larger than the current of the master unit
(minimum of 5% for BHK 500-0.4MG) due to the voltage drop on the wire connect-
ing the internal sensing resistor to the externally accessible terminal TB1-2 (see
Figure 3-25).
RECOMMENDED PROCEDURE.
The following steps are recommended to ensure the combi-
nation of power supplies (power assembly) configured for parallel master-slave operation is
connected and set up properly for current mode operation. Identical models are recommended
for parallel operation.
1. With the units turned off, perform all external wiring (see Figure 3-25). If possible, use a
properly rated switch between the power supply and the load.
2. Apply power to the units:
a. If a load switch is used, close the switch. Set POWER switch of both units to up position
to turn power on.
b. If load switch is not used, Set POWER switch of both units to up position to turn power
on, then press OUTPUT ON/OFF key once on each unit to disable the output.
Summary of Contents for BHK 1000-0.2MG
Page 2: ......
Page 6: ......
Page 17: ...BHK MG032816 xi FIGURE 1 1 BHK MG SERIES PROGRAMMABLE POWER SUPPLY ...
Page 18: ...xii BHK MG032816 ...
Page 46: ......
Page 101: ...BHK MG OPR 032816 3 55 FIGURE 3 20 SERIES AUTOMATIC CONFIGURATION ...
Page 109: ...BHK MG OPR 032816 3 63 FIGURE 3 23 PARALLEL AUTOMATIC CONFIGURATION ...
Page 114: ...3 68 BHK MG OPR 032816 FIGURE 3 25 PARALLEL MASTER SLAVE CURRENT MODE CONFIGURATION ...
Page 116: ......
Page 154: ......