BHK-MG (OPR) 032816
1-3
OUTPUT CHARACTERISTICS (CONTINUED)
Temperature effect
(per degree C)
Voltage 0.01% E
O
max
Ambient temperature
0 to 50° C
Current 0.02% I
O
max
Time effect
Voltage 0.01% E
O
max
0.5-8.5 hours
Ambient temperature: 25° C
Current 0.02% I
O
max
Ripple
(rms/p-p)
Voltage: Fast
Mode
Slow Mode
0.002% / 0.02% E
O
max
0.001% / 0.01% E
O
max
Minus output terminal connected to GND.
Voltage: Nominal load
Current: Short with calibrated shunt.
Fast Mode = internal output
capacitor not connected.
Slow Mode (default) = internal
output capacitor connected
Current: Fast
Mode
Slow Mode
0.02% / 0.2% I
O
max
0.01% / 0.1% I
O
max
Programming
rise time (R)/fall time (F)
Voltage: Fast
Mode
Slow Mode
180
s (R)/180
s (F)
90ms (R)/175ms (F)
Load
E
O
max/I
O
max,
Vout between zero and E
O
max, measured
between 10% and 90% of E
O
max
Current: Fast
Mode
Slow Mode
200
s (R)/200
s (F)
90ms (R)/175ms (F)
Load
E
O
max/I
O
max,
Iout between zero and I
O
max, measured
between 10% and 90% of I
O
max
Transient recovery to load
change (Amplitude/time con-
stant)
Voltage Fast
Mode
Slow Mode
5% E
O
max/100
sec
0.5% E
O
max/1 msec
Vout=400 Vdc and load switched between
infinity and 400/I
O
max
Current
Fast Mode 50% I
O
max/100
sec
Iout = I
O
max
and load switched between
0.1 x E
O
max/I
O
max and
E
O
max/I
O
max
Small signal 3-dB Bandwidth
(Fast Mode)
Voltage 2.5 KHz
Load = E
O
max/I
O
max,
Vprog out = 200V d-c (from keypad)
Vv analog in = 0.2 V rms (from analog
input terminal)
Current 2.3 KHz
Load = E
O
max/I
O
max,
Iprog out = 200 x I
O
max/E
O
max (from
keypad)
Vc analog in = 0.2 V rms (from analog
input terminal)
Slew rate (Fast Mode)
Voltage >1.2% E
O
max (V/
s)
Load
E
O
max/I
O
max,
Measured as the chord of the exponential
response to a square waveform between
zero and E
O
max and back to zero.
Current >1.1% I
O
max (mA/
s)
Load = calibrated shunt
Measured as the chord of the exponential
response to a square waveform between
zero and I
O
max and back to zero.
Overshoot
None
Turn ON/OFF
Output Impedance
See Table 1-1.
Remote Sensing Range
(default = local sensing)
0.5 V d-c per lead
Provisions for 4-terminal (Kelvin) connec-
tion to load
D-C Isolation voltage
BHK 300-0.6MG,
BHK 500-0.4MG,
BHK 1000-0.2MG
1KV d-c or p-p plus max.
output voltage
Between either output terminal and ground
BHK 2000-0.1MG 0.5KV d-c or p-p plus max.
output voltage
Between either output terminal and ground
TABLE 1-2. BHK-MG 200W SPECIFICATIONS (Continued)
SPECIFICATION
RATING/DESCRIPTION
CONDITION
Summary of Contents for BHK 1000-0.2MG
Page 2: ......
Page 6: ......
Page 17: ...BHK MG032816 xi FIGURE 1 1 BHK MG SERIES PROGRAMMABLE POWER SUPPLY ...
Page 18: ...xii BHK MG032816 ...
Page 46: ......
Page 101: ...BHK MG OPR 032816 3 55 FIGURE 3 20 SERIES AUTOMATIC CONFIGURATION ...
Page 109: ...BHK MG OPR 032816 3 63 FIGURE 3 23 PARALLEL AUTOMATIC CONFIGURATION ...
Page 114: ...3 68 BHK MG OPR 032816 FIGURE 3 25 PARALLEL MASTER SLAVE CURRENT MODE CONFIGURATION ...
Page 116: ......