3-2
BHK-MG (OPR) 032816
3.2.1.4
KEYPAD FUNCTIONS
Keypad functions are listed in Table 3-2. Six keys have dual functions, depending on whether
the power supply is in command entry status (waiting for a command to be entered), or data
entry status (waiting for a number to be entered). Command entry status is indicated by a blink-
ing colon
(:_:_:)
and data entry status is indicated by a blinking equal sign
(=_=_=)
.
NOTE: Keys with dual functions are labeled with both a command and a number. The com-
mand label is referred to when the unit is in
(:_:_:)
command entry status; the num-
ber is referred to when the unit is in
(=_=_=)
data entry status.
TABLE 3-1. LCD MESSAGES
LOCATION
MESSAGE
DESCRIPTION
Top left
Loc/Rem
Digital control status: either Remote or Local
top right
CV/CC
Constant voltage mode/constant current mode
Bottom
left:
in command entry
n.nV
Actual output voltage
In data entry
(parameter)
e.g. OVset if OV SET key was pressed.
Bottom middle:
(:_:_:)
Command entry status
Top or Bottom middle:
(=_=_=)
Data entry status
Bottom
right:
in command entry
n.n mA
Actual output current.
In data entry
n.n V or n.n mA
Present programmed value of parameter, replaced by data entered.
TABLE 3-2. KEY FUNCTIONS
KEY
POWER SUPPLY
STATUS ACTIVE
DESCRIPTION
REFERENCE
PARAGRAPH
OUTPUT
ON/OFF
Command Entry
If top line of LCD reads Digital is OFF, press to enable the output. If output is on,
press to disable the output controlled by digital means (keypad or GPIB setting).
If analog control used, analog input must be turned off separately to disable the
output.
3.2.7
V SET
Command Entry
Press to set output voltage. After V SET is pressed, previous setting is dis-
played. Data entry required to enter new value of output voltage; press ENTER
to accept displayed value.
3.2.9
I SET
Command Entry
Press to set output current. After I SET is pressed, previous setting is displayed.
Data entry required to enter new value of output current; press ENTER to accept
displayed value.
3.2.9
LOCAL
Command Entry
If the power supply is in remote mode, keypad is disabled except for LOCAL
key. Press to enable keypad. If LCD reads KEYPAD LOCKED, the LOCAL key
is also disabled and can only be unlocked by remote operation.
3.2.4, B.84
RESET
Command Entry
Press to restore the power on default values: CV mode, output voltage = 0, out-
put current value chosen from the POWER-UP OR RESET CURRENT sub-
menu, overvoltage and overcurrent values per Table 1-2.
3.2.8
Summary of Contents for BHK 1000-0.2MG
Page 2: ......
Page 6: ......
Page 17: ...BHK MG032816 xi FIGURE 1 1 BHK MG SERIES PROGRAMMABLE POWER SUPPLY ...
Page 18: ...xii BHK MG032816 ...
Page 46: ......
Page 101: ...BHK MG OPR 032816 3 55 FIGURE 3 20 SERIES AUTOMATIC CONFIGURATION ...
Page 109: ...BHK MG OPR 032816 3 63 FIGURE 3 23 PARALLEL AUTOMATIC CONFIGURATION ...
Page 114: ...3 68 BHK MG OPR 032816 FIGURE 3 25 PARALLEL MASTER SLAVE CURRENT MODE CONFIGURATION ...
Page 116: ......
Page 154: ......