3-22
BHK-MG (OPR) 032816
FIGURE 3-3. RS 232 IMPLEMENTATION
Only three control characters (characters between 00
H
and 1F
H
) are acknowledged by the
power supply:
•
Carriage Return (CR, 0D
H
)
•
Line Feed (LF, 0A
H
)
•
Back Space (BS, 08
H
)
BS deletes the last character entered, with the exception of CR or LF characters. Either the CR
or LF character acts as the line terminator, initiating parsing of the ASCII data sent to the BHK-
MG by the command originator. When the line is parsed, the BHK-MG sends the line terminator
sequence CR LF to the command originator.
All non-control characters are sent via the serial port of the command originator. The control
character BS is echoed as BS Space BS. Only the first control character is returned in response
to either a CR LF or LF CR character sequence (see Figure 3-3).
3.4.3.1
ECHO MODE
In echo mode each byte (character) is echoed back to the sender where it is verified as the
same character that was just sent.
All non-control characters are sent via the serial port of the command originator. The control
character BS is echoed as BS Space BS. Only the first control character is returned in response
to either a CR LF or LF CR character sequence (see Figure 3-3).
3.4.3.2
PROMPT METHOD
The command originator sends a message line (command) to the BHK-MG and waits until the
prompt sequence CR LF > (3E
H
, 62
10
) is received. The BHK-MG sends the prompt sequence
CR LF > to the command originator indicating the power supply is ready to receive the next
command and data will not be lost.
3.4.3.3
XON XOFF METHOD
The XON XOFF method allows the BHK-MG to control when the command originator is allowed
to send data. The command originator can only send data after the XON (transmission on) char-
acter (011
H
) has been received; the command originator stops sending data after receiving the
XOFF (transmission off) character (013
H
), and waits until the XON character is received before
sending additional data.
Summary of Contents for BHK 1000-0.2MG
Page 2: ......
Page 6: ......
Page 17: ...BHK MG032816 xi FIGURE 1 1 BHK MG SERIES PROGRAMMABLE POWER SUPPLY ...
Page 18: ...xii BHK MG032816 ...
Page 46: ......
Page 101: ...BHK MG OPR 032816 3 55 FIGURE 3 20 SERIES AUTOMATIC CONFIGURATION ...
Page 109: ...BHK MG OPR 032816 3 63 FIGURE 3 23 PARALLEL AUTOMATIC CONFIGURATION ...
Page 114: ...3 68 BHK MG OPR 032816 FIGURE 3 25 PARALLEL MASTER SLAVE CURRENT MODE CONFIGURATION ...
Page 116: ......
Page 154: ......