INSTALLATION. 

Install units in a 19 inch-wide rack. Optional slides may be used. Leave the front

and rear panels clear of obstructions to ensure adequate cooling. For parallel, series and master-slave
configurations, refer to the User Manual.

INPUT CONNECTIONS. 

 Wire the mating source power connector provided (142-0381) for your input

mains (see Table 5 for mains voltage range). The user must provide a properly sized and rated mains
lead (line cord) and service with a current rating compatible with the anticipated input current. Line cords
available as accessories are listed in Table 3. Plug the source power connector into the source power
inlet connector at the rear panel.

LOAD CONNECTIONS. 

Connect the load to the (+) and (–) DC OUTPUT terminals on the rear panel

(Figure 2). (+M) and (–M) outputs are for connection of external monitoring equipment such as a DVM,
oscilloscope, etc.

Configuration of local sensing is facilitated by pre-installed jumpers which configure the unit for local
sensing.as shown in Figure 2.

NOTE: Output Sense lines must be connected for proper operation, either locally, or at the load

(remote). 

FIGURE 1.  KLP SERIES, FRONT PANEL CONTROLS AND INDICATORS

TABLE 5.  INPUT CURRENT SERVICE RATING AND CONDUCTOR SIZES

MAINS VOLTAGE RANGE

CURRENT SERVICE RATING

CONDUCTOR SIZE

100 - 132V a-c, 50/60Hz

20 Amp

#12AWG [2,0 mm²]

180 - 265V a-c, 50/60Hz

15 Amp

#14AWG [3,0 mm²]

POWER ON/OFF

Turns unit on/off.

Circuit Breaker 

gives input 

protection.

VOLTAGE

control/momentary 

switch

Rotate to set 

output voltage. 

Tap to enter 

SETPOINT mode. 

(Also used for 

other functions.)

DC VOLTS

Display shows 

output voltage or 

voltage setpoint. 

(Also used for 

special functions).

CV 

indicator lights 

green when 
operating in 

constant voltage 

mode

Status

Display normally 

blank. Shows 

active function or 

blinks for error 

messages.

CC

indicator lights 

amber when 

operating in 

constant current 

mode

DC AMPERES

display shows 

actual output 

current or

 current set point 

(Also used for 

special functions.)

 

CURRENT 

control/momentary 

switch

Rotate to set 

output current. 

Tap to enter 

SETPOINT mode. 

(Also used for 

other functions.)

DC OUTPUT

indicator lights 

green to show 

output enabled

DC OUTPUT

on/off switch 

enables or 

disables output. 

(Also used to 

accept front panel 

inputs.)

PROTECT

momentary switch

Used to set 

overvoltage and 

overcurrent 

protection limits. 

Requires a thin 

tool (e.g., end of 

paper clip) to 
press switch.

LAN 

indicator

lights green 

when LAN 

interface is

in use

[-1.2K Models]

FUNCTION

momentary switch

Used to access  

calibration,

 GPIB address, 

RS232 baud rate 

(-1200 Models), 

Virtual Model and 

Utility functions. 

Requires a thin 

tool (e.g., end of 

paper clip) to 
press switch.

Summary of Contents for KLP 10-150-3

Page 1: ...ch can be printed as a handy reference Refer to the KLP Developer s Guide for a full description of the digital interfaces their associated drivers and the SCPI command language The User Manual Developer s Guide and drivers are found on the enclosed CD or can be downloaded from the Kepco web site at www kepcopower com support CONTENTS DESCRIPTION 2 UNPACKING 2 EQUIPMENT SUPPLIED 2 ACCESSORIES 3 SA...

Page 2: ... If any indication of damage is found file an imme diate claim with the responsible transport service EQUIPMENT SUPPLIED See Table 2 TABLE 1 MODEL PARAMETERS Model number Rated Voltage Range 1 Maximum current for rated voltage Minimum programmable current Rated Current Range 1 Maximum voltage for rated current Ripple and noise p p 2 Efficiency 115 Va c KLP 10 150 3 0 10V 120A 10V 3 2A 0 150A 8V 15...

Page 3: ... NEMA 6 15R 118 1137 IEEE 488 GPIB Cable 1m long Connect KLP Power Supply to GPIB bus SNC 488 1 IEEE 488 GPIB Cable 2m long Connect KLP Power Supply to GPIB bus SNC 488 2 IEEE 488 GPIB Cable 4m long Connect KLP Power Supply to GPIB bus SNC 488 4 Chassis Slide Allows rack mounted units to slide in and out Two 2 slides required per power supply 108 0239 Jonathan 375 QD Series Analog Connector Backsh...

Page 4: ...an error indication is blinking in the Status display refer to User Manual for an explanation of error codes 3 Rotate VOLTAGE adjust knob clockwise Verify that DC VOLTS display increases in large X 100 increments 4 Press and rotate VOLTAGE adjust knob clockwise Verify the DC VOLTS display increases in finer increments than step 3 then release knob 5 Adjust VOLTAGE adjust knob clockwise until Statu...

Page 5: ...ANEL CONTROLS AND INDICATORS TABLE 5 INPUT CURRENT SERVICE RATING AND CONDUCTOR SIZES MAINS VOLTAGE RANGE CURRENT SERVICE RATING CONDUCTOR SIZE 100 132V a c 50 60Hz 20 Amp 12AWG 2 0 mm 180 265V a c 50 60Hz 15 Amp 14AWG 3 0 mm POWER ON OFF Turns unit on off Circuit Breaker gives input protection VOLTAGE control momentary switch Rotate to set output voltage Tap to enter SETPOINT mode Also used for o...

Page 6: ... S see Figure 2 FIGURE 2 KLP SERIES REAR PANEL VIEW JUMPERS INSTALLED FOR LOCAL SENSING REMOTE SENSING SELECT First remove the factory installed local sensing jumpers between S and M and between M and S Then connect the S and S lines at the load observing proper polar ity see Figure 3 A high frequency bypass network consisting of two capacitors connected across the error sensing point as shown in ...

Page 7: ...anual are Quick Boot eliminating the power up displays use of the internal relay and operation via the LAN interface or analog signals An Installa tion Operation Summary is also included in the User manual The Developer s Guide covers the GPIB and RS 232 and LAN interfaces including the use of the drivers supplied on the CD TURNING THE POWER SUPPLY ON To turn the power supply on set POWER ON OFF c...

Page 8: ... DC AMPERES displays show the actual output voltage and current Before enabling the output ALWAYS check the set points to avoid possible damage to the load 1 Tap either the VOLTAGE or CURRENT control The status display reads SET and the DC VOLTS and DC AMPERES displays show the stored setpoints 2 To accept the displayed value tap the associated adjustment control again To change the value rotate t...

Page 9: ...play does not change since it is showing actual output current Similarly rotating the VOLTAGE control while in CC mode affects the voltage limit To change the limits to a precise value refer to SETPOINT ADJUSTMENT Voltage and current settings are not allowed to exceed either a the virtual model setting or b 80 of the protection value Attempts to set voltage or current beyond these limits will not ...

Page 10: ...tches the output off flashes an overvoltage OVP or overcurrent OCP protection error message on the status display and sets a status bit that can be retrieved through the RS 232 GPIB or LAN port The unit must be cycled on and off to restore the output The maximum values are 1 2 x EOmax for overvoltage protection and 1 2 x IOmax for overcurrent protection A built in feature prevents the unit from be...

Page 11: ...607 228 1616 REV 2 11 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 4 KLP OUTLINE DIMENSIONS SHEET 1 OF 2 ...

Page 12: ...228 1616 REV 2 102607 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 4 KLP OUTLINE DIMENSIONS SHEET 2 OF 2 ...

Page 13: ......

Page 14: ......

Page 15: ...he Company parts or materials for which replacement is requested shall be returned to the Company for examination with shipping charges prepaid by the Purchaser Final determination as to whether a product is actually defective rests with the Company This warranty does not extend to any product which has been subjected to misuse neglect accident improper installation or use in violation of instruct...

Page 16: ...FOLD HERE Please place stamp here KEPCO INC 131 38 SANFORD AVE FLUSHING NY 11355 USA CUT HERE ...

Reviews: