SELENA
Multifunctional LED Clock
USER MANUAL V32D
KERA TECHNOLOGIES INC. 2013
www.ledclocks.com
10
Fn 49
TIMER / COUNTER End-of-Count Alarm ( Buzzer or Relay ) persistence limited to 3 seconds.
Fn 50
MULTI-ZONE slave sync Enable using the Zone Offset in internal memory ( see Fn51 ).
Fn 51
MULTI-ZONE slave Zone Offset programming Enable ( see Fn50 ). Enable this function only to program the zone
offset value.
Disable this function when finished
.
Fn 52
WEEKLY PROGRAMMABLE THERMOSTAT,
HEAT / COOL with AUTO SWITCH-OVER,
32 EVENTS PER DAY separate for each of 7 DAYS, repeated each week.
When selected, this function will enable the programming and operation of up to 32 events/day for each day of
week separately. The thermostat will control up to 2 internal relays; one for Heating and the other for Air-
Conditioning control, or 1 relay for either Heating or Cooling ( A.C. ). Manual override also possible.
Fn 53
MASTER-SLAVE SYNC SIGNAL RANGE EXTENDER-REPEATER function. See description in the manual.
Fn 54
Time Slot Channel selection bit 0 for RANGE EXTENDER ( see Fn 53 ).
Fn 55
Time Slot Channel selection bit 1 for RANGE EXTENDER ( see Fn 53 ).
Fn 56
RESERVED FOR SYSTEM CONFIGURATION , AFFECTS THE SECONDS DISPLAY
( DO NOT ALTER )
Fn 57
STOPWATCH AS PERIOD TIMER with automatic restart of UP TIMER when the External Start input is activated.
NOTE that this option applicable mainly when the EXTERNAL TIMER INPUTS are installed and enabled by
Fn 36
.
The display will show only a steady reading of the last test and is updated each time the START is activated.
Fn 58
External STOP input works like HALT in the STOPWATCH TIMER mode. The timer will be “HALTed” only and can
be resumed by reactivating the START. This feature may also be used when a TIMER ENABLE function is
necessary when the EXTERNAL TIMER INPUTS are installed and enabled by
Fn 36
.
Fn 59
REMOTE CONTROL enabled when EXTERNAL TIMER/COUNTER inputs used.
This function enables the remote control to operate the timer concurrently with the external Start/Stop/Reset inputs
( if installed ).
Fn 60
DAYLIGHT SAVING AUTOCHANGE
( CANADA and USA )
Fn 61
RESERVED FOR SYSTEM CONFIGURATION. CONTROLS ANALOG TEST LIKE TEMPERATURE AND
AUTODIMMING
( DO NOT ALTER ).
Fn 62
TOTAL
DISABLE of REMOTE CONTROL.
(TOTAL Lock-out)
All
subsequent
COMMUNICATION with the clock
via the Remote Control may be disabled by enabling this
function (to prevent unauthorized operation).
Fn 63
PARTIAL
DISABLE of REMOTE CONTROL.
(PARTIAL Lock-out)
All subsequent
PRESETS
of the
CLOCK TIME and FUNCTIONS
via the Remote Control may be disabled by
enabling this function (to prevent tampering with the presets).
Other communication like Timers and dimming will still remain accessible.
To regain the control via the remote, the supply power has to be removed for a few seconds or an optional hardware keypad
must be activated at least once. The clock will then respond to the remote control for appx. 33 seconds allowing for the
removal of this Lock-Out if necessary.
Fn 64
DATE / TEXT display mode selection bit 0 ( see Fn 85 )
Fn 65
DATE / TEXT display mode selection bit 1 ( see Fn 85 )
Fn 66
DATE / TEXT display mode selection bit 2 ( see Fn 85 )
Fn 67
RESERVED
Fn 68
External START input may be used as START/STOP/RESET in the STOPWATCH TIMER mode. The STOP and
RESET inputs do not have to be used. This feature may be used only when the EXTERNAL TIMER INPUTS are
installed and enabled by
Fn 36
.
Fn 69
External START input may be used as START/STOP in the STOPWATCH TIMER mode. The STOP input does not
have to be used. To RESET the timer, the RESET input must still be used. This feature may be used only when the
EXTERNAL TIMER INPUTS are installed and enabled by
Fn 36
.