SELENA
Multifunctional LED Clock
USER MANUAL V32D
KERA TECHNOLOGIES INC. 2013
www.ledclocks.com
11
Fn 70 to Fn 71
RESERVED
Fn 71
Selection of the temperature result display averaging mode as either slow ( Fn71 disabled ) or fast ( Fn71 enabled )
Note, that the slow mode will calculate a more accurate, average reading using several test samples. See also Fn 0,
1, 15, 27, 61, 93, 94 and 95.
Fn 72
TIMERS / STOPWATCH display in the TEXT display section ( see Fn 85 )
Display format:
“ HH-MM-SS-hh “
Fn 73
TIMERS / STOPWATCH display in the TEXT display section ( see Fn 85 )
Display format:
“ Tmr HH-MM-SS “
Fn 74
TIMERS / STOPWATCH display in the TEXT display section ( see Fn 85 )
Display format:
“ TIMER MM-SS “
or
“ TIMER HH-MM “
depending upon the status of Fn 38 and if the timer is
under 1 hour.
Fn 75
TEMPERATURE display in the TEXT display section ( see Fn 15, Fn 85 )
“IN” probe temperature display format:
“ IN XXX C (F) “
Fn 76
TEMPERATURE display in the TEXT display section ( see Fn 15, Fn 85 )
“OUT” probe temperature display format:
“ OUT XXX C (F) “
Fn 77
TEMPERATURE display in the TEXT display section ( see Fn 15, Fn 85 )
“IN” probe temperature display format:
“ TEMP XXX C (F) “
Fn 78
JULIAN DAY display in the TEXT display section ( see Fn 85 )
Fn 79
REAL TIME CLOCK display in the TEXT display section ( see Fn 85 )
( Display format selectable by Fn 8 and Fn 84 )
Fn 80
TIME ZONE / Customer TEXT DISPLAY ENABLE ( see Fn 85 )
Fn 81
EXTRA DATA transmitter enable in Master-Slave system. ( see Fn 34, 53, 82 )
When enabled in the Master or Repeater ( see Fn53 ) clock that is a part of the Master-Slave system, some data,
like the temperature, will be transmitted to the slave clocks.
Fn 82
EXTRA DATA receiver enable in Master-Slave system. ( see Fn 34, 53, 81 )
When enabled in the Slave that is a part of the Master-Slave system, some data, like the temperature, will display as
in the Master clock.
Fn 83
SLAVE INTERNAL RELAY CONTROL ENABLE.
When enabled in the Slave that is a part of the Master-Slave system, the internal relay will be set to the same state
as the relay in the Master clock. ( see Fn 34, 53 )
Fn 84
AM/PM text
indicator enable for 12 hour format of the clock time display in 6-digits clocks or in text ( see Fn 8 )
Fn 85
DATE / TEXT , ZONE
TEXT
and other text formats display
ENABLE.
This function must be enabled to display any data in the text section.
Fn 86
TIME ZONE / Customer
TEXT
DISPLAY
programming
ENABLE
( see Fn 80 )
Enable this function only to program the contents of the Zone Text display.
Disable this function when finished
.
Fn 87
UP Timer/Stopwatch with a PRESET value. When enabled, it will cause the timer to count up from 00:00:00 and
stop at the preset value. The Alarm relay and/or buzzer activation at the end of the count-up is possible ( see Fn
16,17,18 and Fn37 ). A Cycling (looping) timer mode is also available ( see Fn 28 ).
Fn 88, Fn 89
Communication speed ( Baud rate ) selection for RS232 , RS485 and wire-less communication.
OFF, OFF = 9,600 BPS
OFF, ON = 1,200 ( or 4,800 ) BPS
ON, OFF = 600 BPS
ON, ON = 300 BPS
Fn 90
SYNCHRONIZE the SECONDS ONLY in the slave in the Master-Slave system.
When enabled in the slave, this function will cause the slave to update ONLY the seconds in the time clock .
This feature may be used when a different time zone is needed on some selected slaves.
Fn 91
SYNCHRONIZE the MINUTES AND SECONDS ONLY in the slave in the Master-Slave system.
When enabled in the slave, this function will cause the slave to update ONLY the minutes and seconds in the time
clock . The sync will be executed on the 5th minute of each 10-minute period.