background image

NXT-6RK Proximity Reader and Keypad

Installation Guide

Page 6 of 7

P/N: 01217-001 Rev. A

4.3

Verifying RIM Configuration

The corresponding reader type and line control mode LEDs are illuminated during operation. Refer to 
the Drawing on page 1 for switch and LED locations, and the Table on page 2 for switch and LED 
definitions to confirm your configuration settings.

Table 2: RIM LED Guide

LED

Reader Type

D4

Keri MS Series

Keri factory default setting

D5

Wiegand

D6

NXT-6RK

D7

Wiegand Reader/Keypad Combo

LED Control

D1

single wire LED control –  red, green, amber, off

D2

two wire LED control –  red, green, amber, off

Keri factory default setting

D3

a

a. This table is valid for RIM Firmware v03.01.06 and later. Please upgrade your firmware as necessary.

single wire LED control – red, green, off

standard setting for Wiegand Readers using a single wire to drive the 

LED (no amber)

Communication Active

D8

RS-485 Bus

J2 Reader Power Setting

D10

lit when set for 12 VDC reader power

Summary of Contents for NXT-6RK

Page 1: ...erating at 12 VDC Read range may be affected by local installation conditions Read range will be reduced when mounted on metal This equipment has been tested and found to comply with the limits for a...

Page 2: ...n voltage at the end of the cable run Ensure the appropriate power and current for your device is available at the device at the end of the cable run Heavier gauge cable reduces this effect NOTE Keri...

Page 3: ...er snaps onto Base Insert screwdriver blade here to remove Cover from Base 3 00 77 mm 4 6 117 mm 0 70 18 mm Reader Cover Reader Base Drill Size for Cable Beeper Access Hole 7 8 Dia 22 mm 3 125 79 mm B...

Page 4: ...umper Settings for Reader Power NXT 6RK Keypad Reader D6 RS 485 Comm D8 Reader Type 1 2 3 4 5 6 7 8 n a Beeper LED n a 12 VDC Ground Data0 Data1 n a Blue Brown n a Red Black Shield Green White n a Bee...

Page 5: ...2 Press SW1 to step through the supported reader types Each press of SW1 will step to the next reader type 3 When the D6 LED is lit press SW2 The reader type is now set 4 Now the RIM is ready to conf...

Page 6: ...Guide LED Reader Type D4 Keri MS Series Keri factory default setting D5 Wiegand D6 NXT 6RK D7 Wiegand Reader Keypad Combo LED Control D1 single wire LED control red green amber off D2 two wire LED con...

Page 7: ...ring Drive San Jose CA 95131 Unit 17 Park Farm Industrial Estate Ermine Street Buntingford Herts SG9 9AZ UK Telephone 800 260 5265 408 435 8400 Telephone 44 0 1763 273 243 Fax 408 577 1792 Fax 44 0 17...

Reviews: