background image

 

 

Kermann Technical Developer and Consulting Ltd.

 

 

 

Phone:

 (+36) 1 445 1670 

E-mail:

 info@kermannled.hu  

 

10 

8.

 

Technical datasheet 

 

 

 

Technical datasheet 

Kermann ExProof EasyLight Z1 

 

Dimension (LxWxH): 

312,4x136x197,6 mm 

Weight: 

4,21 kg 

Power configurations: 

55W; 43W; 32W; 22W 

Nominal voltage: 

220-240V AC 

Luminaire luminous flux configurations*: 

6550lm; 5240lm; 4010lm; 2925lm**  

Power factor: 

>0,95 

CCT: 

4000K 

Optional CCT: 

3000K, 5000K 

CRI: 

80 

Beam angle: 

60°/90° 

IP class: 

IP67 

IK class: 

IK09 

Dimming possiblity (optional): 

1-10 V DC; 10V PWM 

Electric protection: 

I. class (protected earth) 

Hazardous area category: 

Category II. 

Zone: 

Zone 1. 

Protection mode: 

eb/mb 

Gas group: 

IIC 

Temperature class: 

T5 

Marking: 

1418 

 II 2G Ex eb mb IIC T5 Gb 

Ambient temperature: 

-20 - +45°C 

Surface treatment: 

powder coating 

Installation: 

ceiling, pipe bridge, light pole 

Lifetime: 

50.000 hrs *** 

Made in Hungary 

ATEX 

The above values are for a light source of 4000K 80CRI 

The tolerance range for each value shall be as set by the MSZ EN 60598-1 and MSZ EN 60598-2-1 

standards. 

The technical specifications might vary on a case-by-case basis! 

* optical lens dependent 
** at ta=25°C ambient temperature 
*** L70B50 50.000 hrs @40°C 

 

 

 

 

Summary of Contents for ExProof EasyLight Z1

Page 1: ...OPERATING MANUAL Kermann ExProof EasyLight Z1 explosion proof LED luminaire Dokumentum sz ma K19EXGK02E Rev 30 01 2020...

Page 2: ...contents Overview 3 1 General description of the product 3 2 Components of the appliance 4 3 Installation and startup 5 4 Operational conditions 7 5 Maintenance 8 6 Repair and servicing 8 7 Warranty...

Page 3: ...naires of 2x18W 2x36W and 2x58W high pressure sodium luminaires of 50W 70W and 100W and high pressure mercury luminaires of 50W 80W and 125W in Zone 1 classified hazardous industrial areas for general...

Page 4: ...main components of the luminaire are shown on Figure 1 and 2 and are as follows 1 Heatsink 2 Electronic enclosure 3 Cable gland 2 pcs 4 LED cable 5 Electric power cord 6 Fixture hanging bracket 7 Fixt...

Page 5: ...se both mounting bore holes to fix the plate properly The plate can be fixed into place with the use of either screws a wire or chain Optionally other attachments can also be fixed to the fixture hold...

Page 6: ...e that the electric power cord and the LED cable is not too tight no load is placed on it and that it is not broken The minimum bending radius shall be 6 times the cable sheath diameter 8 Once the lum...

Page 7: ...5 C When the temperature stays below the minimum level for a longer time period once the luminaire is switched off it might not always be able to be switched back on If the temperature stays above the...

Page 8: ...ohibited If the glass surface on the luminaire gets heavily polluted the heat impact of the light staying within the luminaire might damage the light source Therefore if you notice any major pollution...

Page 9: ...the contract signed with the Customer As a general rule the Warranty conditions shall only be valid under the environmental conditions indicated on the technical datasheet of the Product and shall not...

Page 10: ...iblity optional 1 10 V DC 10V PWM Electric protection I class protected earth Hazardous area category Category II Zone Zone 1 Protection mode eb mb Gas group IIC Temperature class T5 Marking 1418 II 2...

Page 11: ...Kermann Technical Developer and Consulting Ltd Phone 36 1 445 1670 E mail info kermannled hu 11 9 EU Declaration of conformity...

Page 12: ...plicable technical specifications or any other issues related to the Product please do not hesitate to contact us Our contact details are as follows Company name Kermann Technical Developer and Consul...

Reviews: