background image

 

KERN & Sohn GmbH

 

Ziegelei 1 
D-72336 Balingen 
E-Mail: info@kern-sohn.com 

Tel:  +49-[0]7433- 9933-0 
Fax: +49-[0]7433-9933-149 
Internet: www.kern-sohn.com 

 
 
 

Operating instructions 
Finished packaging regulations scale

 

 

 

 

KERN FKTF 

Version 1.2 
11/2015 
GB

 

 
 

 
 
 
 
 
 
 
 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

FKTF-BA-e-1512 

Summary of Contents for FKTF 12K2LM

Page 1: ...1 D 72336 Balingen E Mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating instructions Finished packaging regulations scale KERN FKTF Version 1 2 11...

Page 2: ...9 5 1 Installation Site Location of Use 9 5 2 Unpacking 9 5 3 Mains connection 9 5 4 Battery operation 10 5 5 Connection of peripheral devices 10 5 6 Initial Commissioning 10 5 7 Adjustment 11 5 8 Ad...

Page 3: ...inearity 0 5 g 0 5 g 1 g Adjustment points 1 2 3 kg 2 5 6 kg 2 5 10 12 kg Recommended adjust ing weight M1 not supplied 3 kg 5 kg 10 kg Humidity of air max 80 rel non condensing Stabilization time typ...

Page 4: ...ent points 10 20 30 kg 20 50 60 kg Recommended adjust ing weight M1 not supplied 20 kg 10 kg 50 kg Humidity of air max 80 rel non condensing Stabilization time typical 3 sec Allowable ambient tem pera...

Page 5: ...from the nominal filling quantity stipu lated in section 3 3 The allowable minus deviations are as follows Nominal filling quan tity QN in g or ml Admissible minus deviation in of QN in g or ml 5 to 5...

Page 6: ...tested According to the admissible maximum num ber of errors for the verified weighed result e Nominal filling quantity QN for packaged goods in g or ml Maximum admissible verification value in g Less...

Page 7: ...operate balance in explosive environment The serial version is not explosion pro tected The structure of the balance may not be modified This may lead to incorrect weighing re sults safety related fa...

Page 8: ...lf when unpacking for possible visible damage In case of visible damage have the damage verified by the messenger s signature Do not alter goods or packaging and do not remove any parts of the deliver...

Page 9: ...ampness for longer periods of time Non permitted condensation condensation of air humidity on the appliance may occur if a cold appliance is taken to a considerably warmer environment In this case acc...

Page 10: ...cal value for operational safety turns off the scale 5 5 Connection of peripheral devices Before connecting or disconnecting of additional devices printer PC to the data interface always disconnect th...

Page 11: ...al conditions A short warming up time of ca 15 minutes is rec ommended for stabilization 5 9 Verification General introduction According to EU directive 90 384 EEC balances must be verified if they ar...

Page 12: ...the screen Start scale by touching the touch panel Start up screen After contact the Touches and start up the scale the following screen appears To start the measurement it must necessarily be given...

Page 13: ...FKTF BA e 1512 13...

Page 14: ...14 FKTF BA e 1512...

Page 15: ...FKTF BA e 1512 15...

Page 16: ...ocation number Number article number or code Machine enter the machine num ber Tara weighing type Tara previous Tara afterwards Tara average Description product name Density density value of the artic...

Page 17: ...the verification switch is active After entering a setpoint the ohter limits are auto matically calculated according to the statutory FPVO regulation On page 3 of the item you will get insight into th...

Page 18: ...8 FKTF BA e 1512 6 3 Operating mode settings Please press on the start up screen the MENU CAL button Then select in the menu the Configu ration button Now Setting control mode appears This also choose...

Page 19: ...verification switch must then be acti vated in this case Histogram The histogram printout will be activated and displayed in the respective product data Statistic The statistic printout will be activ...

Page 20: ...operator If no operator is available they must be re entered via MENU Memory Operator Description Now in the second information row the selected user appears see ar row Now press the ARTICLE button S...

Page 21: ...ws 6 5 Start the measurement To start the measurement please press STRT MEAS key The different types of measure ment average Tara Tara previ ous Tara afterwards can be se lected in each article In thi...

Page 22: ...red value is within the tolerance between TU and TO passed the upper limit TO below the lower limit TU After the last measurement object the scale displays Ready and the series of measurements can be...

Page 23: ...setting and 19200 Baud Sub D plug 9 channel required For operation with interface faultless operation is only ensured with the correct KERN interface cable max 2m Pin allocation of the balance output...

Page 24: ...nce from the operating voltage Please do not use aggressive cleaning agents solvents or similar agents but a cloth dampened with mild soap suds Ensure that no liquid penetrates into the device and wip...

Page 25: ...played weight is permanently changing Draught air movement Table floor vibrations Weighing plate has contact with other objects Electromagnetic fields static charging choose different location switch...

Page 26: ...e le produit auquel se rapporte la pr sente d claration est conforme aux normes cit es ci apr s I Dichiarazione di conformit Dichiariamo con ci che il prodotto al quale la presente dichiarazione si ri...