54
REGULAR MAINTENANCE
MAINTENANCE
WARNING!
When pumping fuel out of the tank, be sure to put out all flames, and unplug the Unit, other-
wise it may cause imperfect combustion.
Water Drain/Oil Drain of Fuel Receiver
In such case that water is mixed into fuel, and that stops combustion, take the following steps to
drain water.
1.
Unplug the Unit.
2.
Remove fuel strainer.
See the steps for the cleaning of fuel filter on the
previous page.
3.
Drain water/liquid combustible for mobile heater.
Insert a fuel feeder through a hole on the back panel, and
pump out the content.
4.
Replace the fuel strainer.
Wipe out dripped water/oil around the strainer.
Absorb wasted water/oil into used newspapers and dispose them,
If imperfect combustion remains despite of the above procedure, contact your local distributor or
the nearest customer service agent.
It is recommendable to conduct the following regular maintenance at least
once every two years.
Every component parts of the Unit goes inferior in quality as time passes.
It is suggested that regular check-up be taken once every two years so as to maintain the Unit at
its best.
For more details on regular maintenance, contact your local distributor or the nearest customer
service agent.
Component parts subject to replacement:
Following items are tend to wear out in the long term of use;
.......Packing materials, fuel filter
Following items are tend to be affected by poor quality oils;
.......Electromagnetic pump, oil duct, burner body, frame rods, fuel filer, burner head (metal net)
FRONT