background image

WARRANTY

Kerrick Group of Companies warrants this product against defects in material and workmanship for a period of 
12 months from the date original purchase by the first purchaser as shown on the warranty registration card 
supplied with the product.

If, within the period of the warranty, the purchaser returns to our factory or authorised Kerrick service outlet with 
satisfactory evidence of purchase date freight prepaid for both delivery and return, any parts or product claimed 
to be defective, Kerrick will, at its option, repair or replace any such defective parts if Kerrick deems them to be 
defective. The purchaser shall, however, be responsible for any removal or installation charges relating to the 
said parts and such replacement or repair shall constitute the sole liability of Kerrick and the sole remedy of the 
purchaser.

Without limiting the generality of the foregoing, but subject to any relevant statute, this warranty shall not cover 
replacement or repair on account of fair wear and tear, faulty operation contrary to Kerrick's printed instructions, 
unauthorised repair or alteration, negligence, misuse, incorrect operation or accident, failure to service filter or 
motor flooding, or using domestic designed equipment for commercial or industrial purposes.

No warranty is given for equipment that has been serviced or repaired by Kerrick. other than for new parts supplied 
during such repair.

This warranty is given in lieu of all other warranties, whether express or implied, all of which are hereby excluded, 
subject nevertheless to any applicable provision of any act or statute.

Sydney 

98 Carnarvon Street, Silverwater, 2128.  

(02) 9737 9797

Melbourne  20 Egan Road, Dandenong, 3175.  

(03) 9769 2577

Brisbane 

126 Robinson Road, Geebung, 4034  

(07) 3865 2551

Perth 

Unit 2 - 91 Leach Highway, Kewdale, 6105  

(08) 9353 5288

Adelaide 

Sales (08) 8340 8060

www.kerrick.com.au

1300 KERRICK

1300  5 3 7 7 4 2

Australia

New Zealand

Auckland 

12 Greenpark Road, Penrose 

(09) 579 2674      

Wellington   106 Hutt Road, Petone 

(04) 568 7344      

Hamilton  

12A Hall Lane, Frankton 

(07) 847 9111

Christchurch   

(03) 365 5886  

Dunedin  

27 Broughton Street, South Dunedin 

(03) 455 1333

www.kerrick.co.nz

0800 2 KERRICK

0800 2 5 3 7 7 4

Summary of Contents for VH HOSPITAL

Page 1: ...OPERATION AND MAINTENANCE OF YOUR QUALITY KERRICK VACUUM CLEANING MACHINE Sales Agent ...

Page 2: ...not in operation remember to switch it off n The cleaner should never be lifted by the electric cable or be unplugged by pulling the cable INTRODUCTION Your new Kerrick Industrial Vacuum Cleaner is a wise investment As a result of product development this equipment has quality durability and consistency built into it and properly treated will give many years of service You will get the best use fr...

Page 3: ...3 ...

Page 4: ... cleaner for emptying or maintenance The cleaner should never be immersed in water Solvents or strong detergents should never be collected or used to clean the machine The manufacturer or supplier shall not be held responsible for any damage caused to persons animals or objects due to incorrect or irrational use or non observance of these instructions Kerrick Vacuum cleaners have C Tick approval N...

Page 5: ...DRY VACUUM MODELS VH103 VH203MEC VH203HK VH515 PULSAR VH HOSPITAL 5 ...

Page 6: ... 240 volt 50Hz 1 phase power 7 Switch on power point switch on machine UNPACKING AND SETTING UP Your Kerrick dry pick up vacuum cleaner comes complete with a full range of accessories designed to make your cleaning task an easy one 1 Lift the vacuum out of the packing by means of the carry handle 2 Insert the flexible hose G into the tank inlet F and press until you hear a click lock 3 Screw top w...

Page 7: ...head and cloth filter B gently shake cloth filter before removing it from tank Carry tank E to disposal area and tip Make sure no dust or dirt is inside filter 10 Shake cloth filter clean 11 Then using a stiff brush throughly clean the cloth filter surface The cloth filter can be removed from the cloth filter ring and washed by hand or machine Thoroughly dry cloth filter prior to refitting to mach...

Page 8: ...C Tick approval All Kerrick Wet Dry Vacuum cleaners are fitted with double insulated motors N41005 ACN 001 776 709 Ph Tank Model 36mm Accessories 004 617 616 632 For accessory reorder use part numbers above 004 38mm Hose Accessory P No 008 003 006 039 Schematic view Head Tank and Tool Configuration 8 ...

Page 9: ...k inlet G and press until you hear a click lock 3 For machines using 36mm tools follow instructions for assembly described on page 6 and 7 For machines with 38m tool sets fit the two piece extension tube set F together with the suction regulating hole on top NOTE Top extension tube has a black suction regulating control knob turn knob fully to right clockwise for maximum suction This knob allows t...

Page 10: ...ls Z 6 If you are using your Kerrick Vacuum Cleaner for wet pick up first ensure that the cloth filter and the cloth filter support are removed from the tank Detach head clamps K lift head of tank remove cloth filter and support ring J replace head and re attach clamps K 7 When using your machine for dry pick up ensure that the cloth filter assembly is in place before use NOTE Failure to use the c...

Page 11: ...e replaced at least every 12 months TO EMPTY AFTER WET VACUUMING 11 Detach head clamps K remove head wheel tank to disposal area and tip fluid from tank On certain PHD tank models tank emptying can be quickly done using the tank drain hose 12 Dry tank thoroughly prior to re assembly of machine The underside of the motor head is fitted with a float H which when wet vacuuming prevents the container ...

Page 12: ...heck for correct operation of high water level cut off float device Ensure float is free to operate and that the seat on the underside of the motor housing is in good condition and the float gauze cage is clean wash out tank with clean water after use This prevents the building up of bacteria which could occur if machine is left uncleaned for long periods of time prevents unpleasant odours from oc...

Page 13: ...Purchaser s Name Address P Code Phone No Date of Purchase Model No Serial No Dealer Name Invoice No NEW ZEALAND WARRANTY REGISTRATION This section after completion should be detached and mailed to Kerrick New Zealand as soon as possible after purchase to ensure your warranty entitlement is registered Purchaser s Name Address P Code Phone No Date of Purchase Model No Serial No Dealer Name Invoice N...

Page 14: ...DUSTRIAL EQUIPMENT A C N 001 776 709 P O BOX 6367 SILVERWATER N S W 1811 AUSTRALIA KERRICK INDUSTRIES LTD PO BOX 12 093 PENROSE AUCKLAND NEW ZEALAND PLEASE AFFIX POSTAGE STAMP HERE PLEASE AFFIX POSTAGE STAMP HERE ...

Page 15: ...hes coals burning cigarette butts solvents explosive liquids vapours caustic or acids 4 Clean and or replace filter monthly DRY USE Always vacuum with cloth filter assembly in Do not attempt to vacuum water or liquids with cloth filter fitted WET USE Remove the cloth filter and cloth filter frame prior to vacuuming water or liquids A safety float will shut of the vacuum should the liquid level rea...

Page 16: ...t of fair wear and tear faulty operation contrary to Kerrick s printed instructions unauthorised repair or alteration negligence misuse incorrect operation or accident failure to service filter or motor flooding or using domestic designed equipment for commercial or industrial purposes No warranty is given for equipment that has been serviced or repaired by Kerrick other than for new parts supplie...

Reviews: