When the accumulative running time of the fan is ≥30 days, the machine can
continue to run, but it will prompt " " and it will not be able to be removed
even restarted.
In power-off status, long press the "Function" button for seconds, then the
display screen will show once, the " " prompt will be released, and the
fan running time will be cleared.
OPERATION
INSTRUCTIONS
- 5 -
Special Note:
To avoid any damage to the dehumidifier, the compressor features a
"3 minutes delay protection" function, which is, when the dehumidifier is
powered, the compressor can only start again 3 minutes later after its last
shutdown.
●
After the device is powered on, it will automatically resume the working
status before power off.
●
If the machine is running before power outage, the machine will
automatically enter power-on status, and maintain the previous setting
parameters.
●
If the machine is shut down before the power outage, then the machine
will still be in power-off status.
When the dehumidifier is running at a lower temperature, the system will
automatically determine whether there is a presence of frost. If any frost
exists, it will defrost automatically.
The fan will keep running and the compressor will stop when defrosting.
After this process, the compressor will restart to run.
When the ambient temperature is higher than the default high temperature
of 113°F, the system will enter high temperature protection, the small
number will indicate "HH", and the compressor will stop;
When the ambient temperature is lower than the default low temperature of
39 °F, the system will enter the low temperature protection, the small
number will indicate"LL", and the whole machine will stop.