Check the information below for troubleshooting steps, it will save you time to resolve 
issues that may happen with the unit.

The list includes most of the common cases, but not the results of defective unit, crafts 
or materials in the unit.

lf all troubleshooting steps have been exhausted and the issue is still occurring, please 
feel free to reach out to Waykar Customer Seryice to get further assistance.

Water tank is not placed in a 
proper position

Pull out the water tank and put it 
back properly in the machine and 
make sure the tank is empty.

Room temperature is too high or 
too low: above 95

 or below 41

℉.

This product does not apply to 
over hot or cold environment, the 
machine will automatically enter 
the protection mode in this 
condition.

Room temperature is between 
41

(5

) and 68

 (20

)

The machine will automatically 
defrost when running under lower 
ambient temperature, which is a 
normal phenomenon. It will restart 
dehumification again until the 
defrosting process finished.

Is the ambient humidity lower or 
reaching the preset humidity 
level? (When the room humidity 
has reached or lower than the 
preset level, the dehumidifier 
will enter the Standby Mode)

Please set the humidity by 5%RH 
lower than the room humidity or 
set the humidity to 30%RH.

This is to prevent the frequent 
start of the machine. Does the 
machine stop working just now?

FAULTS AND 
PROCESSING METHODS

Summary of Contents for PD606A

Page 1: ...Commercial Dehumidifier PD606A Please read the manual carefully before using the unit USER MANUAL www kesnos com...

Page 2: ......

Page 3: ...Please read the manual carefully to ensure proper use of the dehumidi er Our dehumidi ers are widely used in family bedrooms bathrooms basements o ces and storage rooms etc The dehumidi ers from Kesn...

Page 4: ...BEFORE FIRST USE...

Page 5: ...Warranty Contact Us 14 Statement TABLE OF CONTENTS The graphics and functions provided in this manual may not be the same as the actual product Please always refer to the actual product The model of t...

Page 6: ...cleaning the device or the lter trap and any other part of the machine Do not use the extension cable to connect with power ask the professionals for the installation when there are no proper socket...

Page 7: ...idi er is used for reducing the air moisture of its installation space to a proper level so as to t people in the daily life and material storage Elegant in shape compact in size and convenient in ope...

Page 8: ...down the humidity value 3 Timing key Press to enter the timer setting 4 Function Button Press to confirm the parameters setting Button Description In powered on status press Up Down button to set the...

Page 9: ...e it is off When the machine is defrosting the defrost icon will flash and go out when the defrosting ends OPERATION INSTRUCTIONS 4 Timer Setting This timer setting function is designed for you to set...

Page 10: ...e power outage the machine will automatically enter power on status and maintain the previous setting parameters If the machine is shut down before the power outage then the machine will still be in p...

Page 11: ...PARTS DESCRIPTIONS 6 Control Panel Air Inlet Continuous Drainage Port Hand Button To access the water tank Air Outlet Cable Outlet Caster...

Page 12: ...H INPUT CURRENT 65 F 60 RH IEF F 60 RH 65 MOTOR FLA PD606A 120V 60Hz 1000W 8 8A 515W 4 6A 1 80 liters kWh 0 85A RLA 10A LRA 30A R410A 15 87ozs 450g 800PSIG 5 5MPa 580PSIG 4 0MPa 247PSIG 1 7MPa MOISTUR...

Page 13: ...r Defrost temperature sensor 3 failure Defrost temperature sensor 4 failure Display information transmission abnormal Display information transmission abnormal Note 1 If display E0 E1 E2 E3 E4 ER or E...

Page 14: ...the drainage hose well when drain water conti nuously so as to flow the water freely If work in a cold temperature that could freeze the water then the continuous drainage may not be applicable SPECI...

Page 15: ...10 SPECIAL NOTES...

Page 16: ...transmitted through air such as dust smoke animal fur mold spore and pollen reduce the substances that could cause sensitization lt is suggested to check the filtering mesh regularly make cleaning at...

Page 17: ...oo low above 95 or below 41 This product does not apply to over hot or cold environment the machine will automatically enter the protection mode in this condition Room temperature is between 41 5 and...

Page 18: ...had been removed and the filter has been installed correctly Warning If the dehumidi er is still not working properly as expected and the troubleshooting steps or solutions above may not resolve the...

Page 19: ...14...

Page 20: ......

Reviews: