5.7 Damage to drive unit or sensor field
Never dismantle a drive unit or a sensor field.
Sharp edges can lead to cable damage.
Always have damage to cables immediately repaired by a qualified electrician.
6. Operating function Climber Standard attachment
The CLIMBER slat lifter attachment is controlled by sensor fields which are attached to the front area
at the bottom left and right. If the sensor field is contacted, the slat lifter slats raise and lower
themselves automatically in a vertical direction.
After the CLIMBER slat lifter attachment has been properly installed by a suitable specialist and
connected to the power circuit, it is imperative that a waiting period of 30 seconds is observed since
the sensor field is blocked during this time. The sensor field cannot activate a switching command
during this time. This time is required by the sensor field for self-calibration after being switched on,
and so that no maloperation occurs.
If the sensor button is pressed briefly, the drive starts and stops following the sequence UP, STOP,
DOWN, STOP, UP etc.
The drive stops automatically at the pre-programmed end positions and at the pre-programmed
intermediate positions in the UP direction.
In the DOWN position the drive runs through without stopping at intermediate positions.
If the drive stops at one of the intermediate positions in the UP direction, the following functions are
available.
Press the sensor switch briefly and release it within 1 second: drive will run in the UP direction until the
top end position.
Press the switch for more than 1 second: drive will run in the DOWN direction until the end position.
#