Installation information
Installation with pressure clamping seal
(Article # 48878.01 / 48811.01)
The clamping flange bolts should be tightened to a maximum torque of 4 to 8
Nm (see table) to the sealing membrane. If being installed to protect against
moisture / water DIN EN 18195-5 requires a minimum membrane thickness of
1.2 mm. When sealing hot bituminous membranes to the Ecoguss drain a max
temperature of 400 deg Celsius is allowed for a maximum of 1-2 minutes. The
temperature resistance (220 deg Celsius) of the park drain grill / cover allows it
to be installed in hot asphalt without any precautions.
Installation of
membrane
Lock-&-Lift-System:
Installation of cover
Notice:
with KESSEL key
be sure that cover is inserted under the centering pin!
Notice
Remove the black round gas-
ket which will allow any moi-
sture / water collected on the
waterproof membrane to drain
into the drain body.
Sealing membrane material
Recom. torque
on clamping flange*
Bituminous membrane
4-6 Nm
PIB with bitumous membrane 4-6 Nm
Bituminous with fiber glass
6-8 Nm
Elastomer membrane (48982) 4-6 Nm
(* in accordance to DIN 18195)