background image

Ketotek Technology Inc.

www.cnketotek.com

2

Cooler start to work

w

hen

RT

LS

+

Ld

,

light on.

Cooler stop working when

RT

LS

,

light off. If you

set

PL,

will flash

.

The cooler will delay to work after

the time of

PL

.

Heater start to work

w

hen

RT

LS

-

Ld

,

light on.

Heater stop working When

RT

LS

,

light off.

For example,

we want to control the temperature in

incubator 80

. Differential value 4

. heating socket

connect with light, cooling socket connect with fan.

Set

LS

=80

,

L

d

=4

,

PL

=0,

AH

=100

,

AL

=60

,

CA

=0.

Fan works when

RT

84

. Fan stop working when

RT

<80

.

Light works when

RT

<76

. Light stop working when

RT

80

.

will flash and buzzer alarm if RT>100

or RT<60

.

Light and fan both stop working.

Cooling delay output (PL)

If you set

PL,

in cooling mode, The cooler will not work

immediately.

will flash

.

The cooler will delay to work

after the time of

PL

.

Alarm High/Low Limit Setting (AH, AL)

When measured temperature is higher or equal to AH,

high temperature alarm will be triggered, buzzer will
alarm with

flash until the temperature is lower than AH

or any key is pressed.

When measured temperature is lower or equal to AL, low

temperature alarm will be triggered, buzzer will alarm
with

flash until the temperature >AL or any key is

pressed.

Temperature Calibration CA

When there is deviation between measured temperature

and actual temperature, we can set

CA

value to align

measured temperature and actual temperature. The

corrected temperature = measured tempe

CA

5. Error Description

Heater or cooler does not turn on when specified

temperature is reached?

Check the Ld value you set. Recheck where you put the

sensor. Also check if you set PL. It will make the cooler

output delay

The screen display HHH or LLL?

HHH means the temperature sensor short circuit. LLL

means the temperature sensor open circuit. Buzzer will
alarm with

flash. Press any keys can’t stop alarm. You

need to check the sensor or replace it.

Warning:

The sensor probe is waterproof, but the controller is not

waterproof. Keep the controller away from water.

In each output socket, we use high quality 16A relay

instead of 10A relay in order to improve the performance

in case of overloading.

In order to let controller work under high performance

condition for a long time. We recommend to use max

power

1100W when you use resistive load such as

heating rod, heating pad, electric water heater etc. use max

power

275W when you use inductive load such as

compressor , pump etc.

Warranty

The warranty period of our products is 12 months from

purchase. If a defective is found due to qualified problems

of the product, we will perform three commitments:

repair , replace and refund.