 Test leads 

  Batteries

  Instruction Manual 

  Certificate of conformity

   KEW8112 Clamp adaptor for digital multimeters

   Calibration Certificate

T: 01494 792 212

www.kewtechcorp.com

Email sales-export@kewtechcorp.com

KT117

 

DIGITAL MULTIMETER

 TRUE RMS

  Measures AC/DC current up to 10A

  Measures AC/DC voltage up to 600V

  Auto ranging

  MIN/MAX memory for continuous testing

  Data hold memory function

  Frequency

  Diode test feature

  Capacitance test feature

  Continuity buzzer

  Resistance measurement

  Bar graph indication

  Display: 6000 counts

  Sleep feature to save batteries

  Complies with IEC61010-1 CAT. III 300V / CAT. II 600V

DC V

600.0mV / 6.000 / 60.00 / 600.0 / 600V

(Input Impedance: 10M

Ω

, 100M

Ω

 only 600mV)

±0.5%±2dgt (600.0mV / 6.000 / 60.00 / 600.0V)

±0.8%±3dgt (600V)

AC V

6.000 / 60.00 / 600.0 / 600V

(Input Impedance: 10M

Ω

)

±1.5%±5dgt (6.000V)

±1.2%±3dgt (60.00 / 600.0V)

±1.5%±5dgt (600V)

DC A

600 / 6000µA / 60 / 600mA / 6 / 10A

±1.2%±3dgt (600 / 6000µA / 60 / 600mA)

±2.0%±5dgt (6 / 10A) 

AC A

600 / 6000µA / 60 / 600mA / 6 / 10A

±1.5%±4dgt (600 / 6000µA / 60 / 600mA)

±2.2%±5dgt (6 / 10A)

Ω

600

Ω 

/ 6 / 60 / 600k

Ω 

/ 6 / 60M

Ω

±1.0%±2dgt (600

Ω 

/ 6 / 60 / 600k

Ω 

/ 6M

Ω

)

±2.0%±3dgt (60M

Ω

)

Continuity buzzer

0~600

Ω 

(Buzzer sounds below 100

Ω

)

Diode Check

2.8V Release Voltage: Approx. 0.4mA Test Current

Capacitance

40 / 400nF / 4 / 40 / 400 / 4000µF

Frequency

10 / 100 / 1000Hz / 10 / 100 / 1000kHz / 10MHz

DUTY

0.1~99.9% (Pulse width/Pulse period) 

±2.0%±2dgt (~10kHz)

Display

6040 Counts

Withstand Voltage

AC 3700V / 1min.

Reading Type

TRMS

Applicable Standard

IEC 61010-1 CAT.III 300V Pollution degree 2

IEC 61010-1 CAT.II 600V Pollution degree 2

IEC 61010-031

IEC 61326

Power Source

R6P(1.5V) × 2 (Auto-power-OFF within 15 minutes)

Dimensions

161(L) × 82(W) × 50(D)mm

Weight

Approx. 280g

ACCESSORIES

PRODUCT DATA SHEET

SPECIFICATIONS

OPTIONAL

KT117

Digital Multimeter

t: 01494 792 212

kewtechcorp.com

e: sales@kewtechcorp.com

Summary of Contents for KT117

Page 1: ...INSTRUCTION MANUAL AUTO RANGE DIGITAL MULTIMETER KT117...

Page 2: ...parts in the manual for safe operation of the instrument Be sure to carefully read the instructions following each symbol in the manual DANGER is reserved for conditions and actions that are likely t...

Page 3: ...quipment which is supplied power from a distribution board and cable run from a distribution board to an outlet 2 Features This instrument KT117 is a Digital Multimeter which designed for making measu...

Page 4: ...600V DC or AC rms Note Forward DC current approx 0 4mA Reversed DC voltage approx 2 8V Open circuit voltage approx 0 5V Test condition Note It can not display bar graph on capacitance range It can not...

Page 5: ...ss than 90 Insulation Resistance It should be more than 100M DC1000V between electrical circuit and enclosures Withstand Voltage It should be more than AC3700V for one minute between electrical circui...

Page 6: ...the instrument case 6 1 1 DC Voltage Measurement DCV 1 Insert the black test lead plug into the COM terminal and the red test lead plug into the V Hz terminal 2 Set the Function Selector Switch to pos...

Page 7: ...e circuit 5 Power on the circuit under test 6 Measured value is indicated on the display If you connect the test leads the other polarity symbol is indicated on the display 6 2 2 DC Current Measuremen...

Page 8: ...ke sure that the O L symbol is indicated on the display at this bout then short the test lead tips and check 0 is indicated on the display 3 Connect the test leads to both ends of the resistance under...

Page 9: ...ed on the display Measuring unit nF uF is automatically chosen and indicated due to the measured value Note It may take some time according to the measuring capacitance Measuring capacitance 4uF Measu...

Page 10: ...uto ranging there are following 2ways 1 Press RANGE Key for 2seconds 2 Change to the other functions 7 4 REL Key The difference between measured values can be indicated on the display at each ACV DCV...

Page 11: ...e to remove test leads from the instrument when opening the battery cover in order to replace batteries and fuses 9 1 Battery replacement 1 Remove test leads from the instrument 2 Remove the holster f...

Page 12: ...92 1819A...

Page 13: ...Impedance 10M 1 5 5dgt 6 000V 1 2 3dgt 60 00 600 0V 1 5 5dgt 600V DC A 600 6000 A 60 600mA 6 10A 1 2 3dgt 600 6000 A 60 600mA 2 0 5dgt 6 10A AC A 600 6000 A 60 600mA 6 10A 1 5 4dgt 600 6000 A 60 600mA...

Reviews: