background image

15

EN

WARNING  -  for  the  safety  of  people,  it  is  important 

to follow these instructions and save them for future 

use.

Read the instructions carefully before you start the installation.

The design and manufacture of the devices making 

up the product and the information contained in this 

manual  comply  with  safety  regulations.  However, 

wrong installation and programming may cause seri

-

ous  physical  injury  to  those  who  perform  the  work 

and those who will use the device. For this reason, 

during installation, it is important to carefully follow 

all instructions in this manual.

Do not proceed with the installation if you have doubts of any kind 

and contact Key Automation Customer Service for clarifications.

By the European legislation, the creation of the auto

-

mation of a door or gate must comply with the rules 

laid down in Directive 2006/42/EC (Machinery

 Direc-

tive) and in particular, EN 12445; EN 12453; EN 12635 

and EN 13241-1 standards, which allow the installer 

to declare the compliance of the automation.

In view of this, the final connections to the power supply of the auto

-

mation, the system tests, its commissioning and maintenance must 

be performed by qualified and experienced personnel, according to 

the instructions in "Testing and commissioning of the automation".

Moreover, the personnel shall also take responsibility to establish 

the  tests  related  to  the  risks  involved  and  verify  compliance  with 

the provisions of laws, rules and regulations: in particular, compli-

ance with all requirements of standard EN 12445, which establishes 

methods  of  tests  for  the  verification  of  the  automations  for  doors 

and gates.

IMPORTANT - Before starting the installation, perform 

the following analysis and tests:

Ensure that the individual automation devices are suitable for the 

installation to be made. In this regard, check with particular attention 

the data contained in the "Technical data" section. Do not install if 

even one of the devices is not suitable for use.

Check whether the devices in the kit are sufficient to maintain safety 

and functionality.

Perform risk analysis, which must also include the list of essential 

safety requirements set out in Annex I of the Machinery Directive, 

indicating the solutions adopted. Risk analysis is one of the docu

-

ments comprising the technical file of the automation. This must be 

completed by a professional installer.

Considering  the  hazards  that  may  occur  during  in

-

stallation and use of the product you need to install 

the automation observing the following precautions:

Do  not  make  changes  to  any  part  of  the  automation,  other  than 

those specified in this manual. Operations of this type will only lead 

to malfunction. The manufacturer disclaims any liability for damage 

arising from products modified arbitrarily.

Keep the parts of the components from being immersed in water or 

other liquids. During the installation, ensure that no liquid penetrates 

into the devices.

If liquid spills into any part of the automation components, immedi-

ately disconnect the power supply and contact the Key Automation 

Customer Service. The use of the automation under these condi

-

tions can be dangerous.

Do not place the various components near sources of heat and do 

not expose them to open flame. These actions may damage them 

and cause malfunctions, fire or danger.

All operations requiring the opening of the protective cover of vari-

ous automation components, must be performed with the control 

unit disconnected from the main supply. If the disconnection device 

is not visible, place a "MAINTENANCE IN PROGRESS" sign.

The control unit must be connected to a power supply line provided 

with grounding safety connection;

The product cannot be considered an effective system of protection 

against intrusion. If you want to protect yourself efficiently, you need 

to integrate the automation with other devices;

The product can be used only after the "commissioning" of automa

-

tion has been made, as provided in paragraph "Testing and commis

-

sioning of the automation" ;

Provide the power system with a disconnecting device with a gap 

between contacts enabling full disconnection, under the conditions 

dictated by the overvoltage category III;

For the connection of pipes and conduit or guides, use pipefittings 

with IP55 degree of protection or higher;

The electric system upstream of the automation shall comply with 

current regulations and must be made according to the good indus-

try practice;

It is recommended to use an emergency button to be installed near 

the automation (connected to the STOP input of the control board) 

so that you can immediately stop the gate or door in case of danger;

This device is not intended for use by persons (including children) 

whose physical, sensory or mental abilities are reduced, or who 

have lack of experience or knowledge, unless they have been able 

to benefit, through the intermediary of a person responsible for their 

safety, from supervision or instruction concerning use of the device;

Children should be supervised to make sure they do not play with 

the device;

WARNING  -  The  packaging  material  of  all  compo

-

nents  must  be  disposed  in  compliance  with  local 

regulations.

WARNING - The data and information provided in this 

manual are subject to change at any time without no

-

tice by Key Automation S.r.l.

1 - SAFETY WARNINGS

Summary of Contents for Viper

Page 1: ...Einsatz Instrukcje i zalecenia dotyczące instalacji i użytkowania Instruções e advertências para a instalação e utilização Motoriduttore sezionale per automazione garage Opener for sectional and up and over garage door Motoréducteur sectionnél pour automation garage Motorreductor seccional para automatismo garaje Moto redutor seccional para amolação garagem Przekrojowa przekładnia zwalniająca do a...

Page 2: ...ny part of the automation other than those specified in this manual Operations of this type will only lead to malfunction The manufacturer disclaims any liability for damage arising from products modified arbitrarily Keep the parts of the components from being immersed in water or other liquids During the installation ensure that no liquid penetrates into the devices If liquid spills into any part...

Page 3: ...d of two boxes One contains the package of the automation system the other contains the guide assembly as shown in the illustration below Automation system package Characteristic Name Quantity Automation system 1 Manual 1 Curved arm for door 1 Mounting clamp 2 Support 1 U bracket 3 Support bracket 1 Door bracket 1 Package of various fastening devices 6x15 hex head self tapping screw 8x 6x80 Screw ...

Page 4: ...ail 3320 mm in single piece SEZ7 for sectional doors up to 10 mq with motor 24 Vdc and central with integrated receiver 700Nm chain rail 3320 mm into three pieces with fast joints SEZ12U for sectional doors up to 16 mq with motor 24 Vdc and central with integrated receiver 1200Nm pre assembled chain rail 3320 mm in single piece SEZ12 for sectional doors up to 16 mq with motor 24 Vdc and central wi...

Page 5: ...disconnection under the conditions dictated by the overvoltage category III Ensure that all materials used for the installation comply with cur rent regulations 4 PRODUCT INSTALLATION 4 1 Assembly of chain in 3 parts 1 Line the three pieces of the guide 2 Place the connector at the center of the guide and between the limits position then repeat for the second connector 3 Tighten the nut with a wre...

Page 6: ...body to the guide 6x15 self tapping screw U bracket Guide lateral movement ring 90 rotated head Standard 6x15 self tapping screw U bracket Guide lateral movement ring 4 4 Manual opening of door Guide Carriage Cord In case of power failure 1 If the door is closed Pull the cord and release the clutch to allow the door to be lifted easily 2 If the door is open Pull the cord once to allow the door to ...

Page 7: ...e unit provides a single audible signal and the display indicates 0 in cycles Attention If programming is not complete the settings will be cancelled automatically If incorrect information has been pro grammed power off and then power back on referring to the following 4 8 Setting of opening limit Press the key P for 5 seconds Press Or press The unit emits 1 beep and 1 is displayed Door opening Do...

Page 8: ...ss P to save the settings Press P flashes Press or press to select the level 4 11 Setting force level Press to display 4 Default setting Force level Low High Press P to save the settings C When programming is finished the door must make a full cycle before usage this cycle is used to learn the force after the modification made Note in order to exit the programming and save the parameters push P bu...

Page 9: ...ff Press P to show 0 the func tion is not active default setting Press to show 1 and activate the function The duration auto matic closing is 5 seconds Press or to select the dura tion following the table below Press P again to save the set tings 4 12 Setting reception mode 4 15 Setting of alarm for 2000 operating cycles Default setting off Press to display 8 Press P The display shows 0 to indicat...

Page 10: ...paragraph 4 12 then after memorize transmitters as indicated here below 1 Save Press the S button until 0 appears Release the S button Press the button of the transmitter to be memorised The 0 on the display disappears the transmitter has been saved For the next transmitters maximum 20 repeat the procedure for each single transmitter 2 Deletion of a single transmitter Press and hold the P S button...

Page 11: ...iagram drawing or photo of the installa tion risks analysis and solutions adopted manufacturer declaration of conformity of all devices connected instruction manual of each device and maintenance schedule of the installation Fix on the gate or door a plaque indicating the automation data the name of the person responsible for the commissioning the serial number and year of construction the CE mark...

Page 12: ...utomation can be operated as any normal non automated opening device To do this you must run the manual release the only operation on the automation allowed to the end user Release and manual movement before performing this operation pay attention that the device can be released only when the door is stationary Maintenance Like any machine your automation needs periodic maintenance to ensure its l...