13
10 Notes.
Disp.
Parameter
User
Π100 Fan max work power or max power when Πr 0-10.
n 40 Minimum fan power.
Πh 2 Fan speed decrease coefficient.
Πr 0 Automatic fan speed control and time of fan start.
Πn15 Fan work time.
Πu 6 Fan pause time.
P 40 Central heating pump launch temperature.
Ph 2 Central heating pump hysteresis.
Pc 2 The work mode and pause time of CH pump.
u 50 Tap hot water desired temperature.
uh 5 Hot water heating hysteresis.
ur 0
Work mode of hot water pump:
0 - no hot water,
1 - hot water priority,
2 - no hot water priority,
3 - mixing pump.
L 45 Minimum boiler temperature.
H 85 Maximum boiler temperature.
h 2
Boiler temperature hysteresis.
A 99 Boiler overheating temperature.
Fd2h Fuel shortage testing time with burning.
Fb2h Fuel shortage testing time in WORK mode and burning out.
Ar 0
Work mode of extra output:
0- output turning on extra boiler,
1- alarm output,
2- output controlling mixing valve,
3- output controlling emergency cooling system,
4- output controlling extra devices turning on during work of blow-in
fan.