background image

L2

STATUS) Red light-----Four flickers

Over-voltage protection

L2

STATUS) Red light-----a flicker

Temperature protection

XVIII. Description of driver’s protection functions: controller provides overvoltage,

under-voltage, overheat and over-current protection

1.

Over voltage, under-voltage protection:

when external power supply is higher or lower than

pre-set voltage value threshold, output of controller will be cut off. The range of normal

working voltage is 10-50v. Meanwhile, under-voltage & over voltage value can be set

according to customer’s requirements.

2.

Overheat protection:

Controller contains an internal temperature detection circuit, when

detected temperature exceeds 80

, output stage of controller will be fully off.

3.

Over-current protection:

controller contains an internal current detection circuit, when

detected output current of controller reaches to over-current protection threshold, controller will

enter into over-current protection state.

Note: supposing that driver is under forward start status, when detected working current exceeds the

current threshold, driver will immediately cut off the power stage and stop output. After

troubleshooting, disconnect forward start, connect them again to remove protection.

Jinan Keya Electronic Technology Co., Ltd.
Address: No.78, West Luohe Road, Beiyuan Street, Tianqiao District, Jinan, Shandong, China
250033
Tel: 0531-88975137

88601737

88601217

Fax: 0531-85898028
Website:

www.jnky.com

Summary of Contents for DC12/48RT100BL-XW

Page 1: ...DC12 48RT100BL XW Driver Operation Manual Jinan Keya Electronic Technology Co Ltd...

Page 2: ...nces Please make sure that necessary protectors are mounted between power input end of this device and power supply storage battery to avoid accidents or fatal damages Devices need to be mounted over...

Page 3: ...be widely used in automation control industry II Specifications and Model Max Max DC voltage Output current Output voltage Input range Model AC A DC V DC V DC12 48RT100BL XW 100 50 10 50 III Character...

Page 4: ...100 11 Digital quantity output interface Maximum load capacity is 50v 1A 12 Temperature protection status stops output at 80 13 Operating temperature 30 60 14 Environment humidity relative humidity 80...

Page 5: ...s voltage and current shall be selected for the device Specifications of power input line and motor connecting line selected for the driver are shown in following table Table 1 Specification and leng...

Page 6: ...shall not be connected otherwise damages may be caused n order to reduce unnecessary electronic signal interference length of connecting lines which control the terminal shall be shortened as much as...

Page 7: ...et shall be single ended grounded IX Analog quantity control External 0 5V control WARNING Be sure to use shielded wire for standard signal input and shielding net shall be single ended grounded Be su...

Page 8: ...nnected i e forward run Backward start BW and COM shall be shorted connected i e backward run Note In case that COM terminal is not shorted connected with FW or BW terminal driver is inoperative In ca...

Page 9: ...BW if required by switch functions limit direction which is opposite to moving direction shall be selected for shorted connection Back and forth movement of motor Supposing that initial position will...

Page 10: ...iver provides motor with voltage by M1 M2 terminal blocks Note in case that forward start port is connected on control terminal however motor runs in opposite direction so the driver shall be disconne...

Page 11: ...value of battery main switch to rated current value of motor is 1 3 Confirm whether the battery voltage can meet driver s working voltage requirements and whether battery capacity can bear the load of...

Page 12: ...re detection circuit when detected temperature exceeds 80 output stage of controller will be fully off 3 Over current protection controller contains an internal current detection circuit when detected...

Reviews: