Installation of the AC-1100 includes the following tasks, which are detailed in the sections to
follow:
•
Prepare to mount the reader
•
Set the network address of the reader
•
Connect the RS-485 network cable
•
Connect the power supply cabling
•
Mount the reader
The power supply and network cabling are connected to a four position terminal block fixed in
the resin potting at the rear of the AC-1100 reader.
The terminals can accept wiring up to 1 mm
2
in cross section, which is equivalent to 18 AWG.
The conductors used should not exceed this size.
Please refer to the KeyMaster System Hardware Installation Guidelines, file name ‘AC-6000
HIG Rev B ENG-US.pdf’ for more comprehensive installation information.
Note:
To Prevent EMI between readers, ensure the readers are mounted at least 6” apart.
The terminals are labeled on the rear of the unit as shown in the diagram below.
+1
2 V
d
c
0 V
d
c
-RS
485
+R
S485
Labeled terminal block
The following procedure is used when cables are connected to the terminal block:
•
1/4” of the insulation is carefully stripped from the end of each conductor
•
The terminal screw is loosened
•
The bare portion of the conductor is inserted into the terminal orifice
•
The terminal screw is fastened
The recommended screwdriver is a slot-head type screwdriver suitable for size 0 or size 1
screws (3/32” wide blade). The screws should not be over-tightened as this may damage the
conductor.