NDACS 6000 Quick User Guide.   2004 - 2004 

C:\projects\ndacs6000\manual\booklet\quickuserguide\quickuserguidenadacs6000.doc 

 
Select 

Internet Protocol (TCP/IP)

   

 
The 

Internet Protocol (TCP/IP) Properties

 Window will appear. 

 
Adjust the PC IP address and subnet mask settings to 
 
IP Address:  

23.0.0.110

 

Subnet Mask: 

255.0.0.0 

 

Ensure that the 

OK

  button is selected to confirm the new settings. 

 

5.  Web Browser Settings 

 
In order to examine data and configure the NDACS, the Microsoft 
Internet Explorer 6.0 web browser should have the following 
parameters set. 
 
Start Web Browser. 
 

Tools

 

? ?

Internet Options

?? ?

Advanced 

 

 

 
Internet Explorer 5.0 and 5.5 can be used and should be configured as 
above, however on some versions of this software the Service Pack II 
must be installed. The service pack for the Microsoft Internet 
Explorer is freely available from the Microsoft web site. 
 

6.  Using the NDACS 

 
Once the Web Browser is configured and the PC IP address has been 
set then it is now possible to examine data and configure the 
instrument. 
 
1) Start the Internet Explorer web browser. 
 
2) Enter  

23.0.0.100  

as the browser address.   

The instrument web page will be displayed. 
 
 
 
 
 

 
 
 

 

 
3) Enter default password  "

full

"   --  lower case 

 
There are 3 levels of password protection for the NDACS but to 
allow full configuration of the instrument the default password shown 
above must be entered. The passwords can be user set at any time. 
 
4) The main instrument web page will now be displayed. 
 

 

 
To observe data  -- Select 

View Data

 button 

 
All of the NDACS analogue inputs are preset to accept input signals 
in the range of 0 - 5V. 
 
To read on-line manual -- Select 

View Manual

 button. 

The on-line manual includes comprehensive instructions for all of the 
instruments operations. 
 

 

7.  Modem/WAP Enabled Mobile Phone Connection 

 

The NDACS can be directly connected to an external modem or 
WAP enabled mobile phone. The modem must be Hayes compatible. 
The instrument contains all the software to control the modem or 
WAP phone and automatically answers any telephone call. 

 

Connection to the NDACS 

 

Connect a standard 9 pin PC modem cable between the NDACS and 
the modem or use the data link cable supplied with a WAP mobile 
phone. 

 

Windows 2000/NT Dial-In Account TCP/IP Settings 

 

1) Select Control Panel 

?

 Network & Dial-Up Connections 

2) Select Dial-Up account  
3) Select Properties 
4) Networking 

? ?

Internet Protocol

??

TCP/IP] 

5) Select 

IP Address Automatically Selected  

Tab 

    Select  

DNS Server Address Automatically

  Tab

 

 

Making a Dial-in connection 

 
1) Dial-up the NDACS using a standard dial-up account from a PC 
 
The dial-up account should have  
 
Username = "

NDACS

"   Password = "

NDACS

"  -- lower case 

 
The instrument will automatically answer the incoming call and will 
indicate that it is negotiating the connection with the PC. The 
standard Windows modem icon should appear on the task bar. 
 

Accessing the instrument 
 
1) 

Start a web browser and enter the address 195.20.17.50.   

 
This is the default dial-in IP address setting for the NDACS.  
 
2) The Login web page will appear (as shown for network connection  

above).  

 
Enter password "

full

"  -- lower case. 

 
The main instrument web page will now appear and it will now be 
possible to examine data and configure the instrument.  

Instrument IP Address 