22
Keysight 34931A-34933A User’s Guide
NOTE
On the 34931T terminal block, only two sets of screw terminals are for use with
the 34931A module. See the following drawing.
When using the 34931T terminal block, be sure to
wire your connections to the two sets of screw
terminals closest to the 50-pin D-sub connectors.
Although columns are numbered the same on
Matrix 1 and Matrix 2, they are electrically
separate from one another (e.g., Col C8).
Wire Size:
20 AWG Typical
18 AWG Max