OUTPut:PON:STATe RST|RCL0|AUTO
OUTPut:PON:STATe?
Sets the power-on output state.
Parameter
Typical Return
RST|RCL0|AUTO
RST, RCL0, or AUTO
Set the power-on state to the *RST state: OUTP:PON:STAT RST
RST specifies that the instrument powers on in a state equivalent to *RST.
RCL0 loads the state stored in state storage memory location 0.
AUTO specifies that the instrument powers on in the power-down state. The output state is always off.
This parameter is not affected by
or
.
This parameter is saved in nonvolatile memory.
OUTPut:PROTection:CLEar
Resets the latched protection. This clears the latched protection status that disables the output when
a protection condition occurs.
Parameter
Typical Return
(none)
(none)
Clears the latched protection status: OUTP:PROT:CLE
All conditions that generate the fault must be removed before the latched status can be cleared. The
output remains in the OFF state after the fault condition is cleared.
OUTPut:PROTection:WDOG[:STATe] ON|1|OFF|0
OUTPut:PROTection:WDOG[:STATe]?
Enables or disables the I/O watchdog timer.
Parameter
Typical Return
0|OFF|1|ON
0 (OFF) or 1 (ON)
Enables the watchdog timer protection: OUTP:PROT:WDOG ON
When the watchdog timer is enabled, the output will be disabled if there is no I/O activity on any
remote interface within the time period specified by OUTput:PROTection:WDOG:DELay. The output is
latched off but the programmed output state is not changed.
The watchdog timer function is NOT reset by front-panel activity; the output will still shut down after
the time period has elapsed.
The
command sets this parameter to 0.
3 SCPI Programming Reference
142
Keysight AC6800B Series Operating and Service Guide
Summary of Contents for AC6801B
Page 1: ...Operating and Service Guide Keysight AC6800B Series Basic AC Sources...
Page 16: ...AC6802B 1 Getting Started 16 Keysight AC6800B Series Operating and Service Guide...
Page 17: ...AC6803B Keysight AC6800B Series Operating and Service Guide 17 1 Getting Started...
Page 18: ...AC6804B 1 Getting Started 18 Keysight AC6800B Series Operating and Service Guide...
Page 62: ......
Page 196: ...4 Calibration Verification and Service 196 Keysight AC6800B Series Operating and Service Guide...