CURRent Subsytem
The CURRent subsystem limits the instrument's output current.
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude] <
value
>|MINimum|MAXimum
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]? [MINimum|MAXimum]
Sets the immediate AC current limit in amps (rms).
Parameter
Typical Return
AC6801B 0.1 to 5.2 A
AC6802B 0.2 to 10.5 A
AC6803B 0.4 to 21.0 A
AC6804B 0.8 to 42.0 A
+9.00000E-01
Sets the current limit to 900 milliamps: CURR 900 MA
Current units (UA, MA, A) are allowed.
Values exceeding the instrument's maximum value will be set to the instrument's maximum value.
The
default is the instrument's MAXimum value.
[SOURce:]CURRent:OFFSet[:IMMediate] <
value
>|MINimum|MAXimum
[SOURce:]CURRent:OFFSet[:IMMediate]? [MINimum|MAXimum]
Sets the immediate DC current limit in amps.
Parameter
Typical Return
AC6801B 0.1 to 4.2 A
AC6802B 0.2 to 8.4 A
AC6803B 0.4 to 16.8 A
AC6804B 0.8 to 33.6 A
+3.00
Set the DC current limit to 3 A: CURR:OFFS 3
Current units (UA, MA, A) are allowed.
Values exceeding the instrument's maximum value will be set to the instrument's maximum value.
The
default is the instrument's MAXimum value.
Keysight AC6800B Series Operating and Service Guide
121
3 SCPI Programming Reference
Summary of Contents for AC6801B
Page 1: ...Operating and Service Guide Keysight AC6800B Series Basic AC Sources...
Page 16: ...AC6802B 1 Getting Started 16 Keysight AC6800B Series Operating and Service Guide...
Page 17: ...AC6803B Keysight AC6800B Series Operating and Service Guide 17 1 Getting Started...
Page 18: ...AC6804B 1 Getting Started 18 Keysight AC6800B Series Operating and Service Guide...
Page 62: ......
Page 196: ...4 Calibration Verification and Service 196 Keysight AC6800B Series Operating and Service Guide...