Keysight B1542A User’s Guide, Edition 10
7-15
Status Code and Error Messages
SYSPIV_SMTH_ERROR_PIV_SET_SAMPLING_
NOT_COMPLETED
BFFC10CB
-4299
PlsdivSetSmoothing: Execute
PlsdivSetSampling before this
command.
SYSPIV_ERROR_SMTH_SMTH_NUM_OUT_OF
_RANGE
BFFC10CC
-4300
PlsdivSetSmoothing: Smoothing
number must be 3 to 4001.
SYSPIV_ERROR_STT_PIV_INIT_NOT_COMPLE
TED
BFFC10D0
-4304
PlsdivSetTransTime: Execute
PlsdivInit before this command.
SYSPIV_ERROR_STT_INVALID_TRNAS_TIME
BFFC10D1
-4305
PlsdivSetTransTime: The trans_time
value must be 2 ns to 200 ms.
SYSPIV_ERROR_SVGL_PULSE_WIDTH_NOT_
DEFINED
BFFC10D4
-4308
PlsdivSetVgLevel: Execute
PlsdivSetPulseWidth before this
command.
SYSPIV_ERROR_SVGL_BASELINE_VOLTAGE_
MISMATCH
BFFC10D5
-4309
PlsdivSetVgLevel: Correct the
vg_base value. It must be same as the
system defined value. Or turn on the
gate voltage adjustment function.
SYSPIV_ERROR_SVGL_VG_LEVEL_OUT_OF_
RANGE
BFFC10D6
-4310
PlsdivSetVgLevel: vg_high must be
-
4.5 V to 4.5 V.
SYSPIV_ERROR_SVGL_VG_HIGH_SMALLER_
THAN_BASE
BFFC10D7
-4311
PlsdivSetVgLevel: vg_high must be
greater than vg_base.
SYSPIV_ERROR_SVGL_VG_AMP_OUT_OF_RA
NGE
BFFC10D8
-4312
PlsdivSetVgLevel: Gate pulse
amplitude |vg_high
-
vg_base| must
be > 55 mV and < 4.5 V.
SYSPIV_ERROR_SVGL_INVALID_PULSE_POL
BFFC10D9
-4313
PlsdivSetVgLevel: Polarity of pulse
must be 0: positive or 1: negative.
SYSPIV_ERROR_SVGL_SET_VG_FAILED
BFFC10DA
-4314
PlsdivSetVgLevel: Vg setting loop
was not converged. Change vg value.
SYSPIV_ERROR_SVGL_VG_BASE_OUT_OF_R
ANGE
BFFC10DB
-4315
PlsdivSetVgLevel: vg_base must be
-
3.0 V to 3.0 V.
SYSPIV_ERROR_PUINT_PIV_INIT_NOT_COMP
LETED
BFFC10E0
-4320
PlsdivUninit: Enter PlsdivInit before
this command.
Status Code Name
Status Code
Error
Number
Error Message
Summary of Contents for B1542A Pulsed IV Package
Page 1: ...Keysight Technologies B1542A Pulsed IV Package for B1500A EasyEXPERT User s Guide ...
Page 9: ...1 Introduction ...
Page 18: ...1 10 Keysight B1542A User s Guide Edition 10 Introduction Accessories and Options ...
Page 19: ...2 Installation ...
Page 41: ...3 Performing System Setup and Compensation ...
Page 55: ...4 Performing Measurement ...
Page 68: ...4 14 Keysight B1542A User s Guide Edition 10 Performing Measurement DC I V Measurements ...
Page 69: ...5 PLSDIV Test Definitions ...
Page 108: ...5 40 Keysight B1542A User s Guide Edition 10 PLSDIV Test Definitions Parameters ...
Page 109: ...6 PLSDIV TIS Commands ...
Page 133: ...7 Status Code and Error Messages ...
Page 159: ......