Troubleshooting 5
Series E4360 Service Guide
53
Overall Troubleshooting Sheet 3
End
From Sheet 2
Remote sense
not working?
Check remote sense connections.
Replace the power module.
YES
NO
Downprogrammer
not working?
Replace the power module.
YES
NO
Off voltage
not at zero?
Replace the power module.
YES
NO
Digital port
not working?
Perform bias assembly troubleshooting.
Replace interface assembly.
YES
NO
Remote interface
not working?
Check for latest firmware revision and update if required
Replace interface assembly.
YES
NO
There is either no problem with the
power supply, or the problem could not
be isolated with this proccedure.
Perform the verification procedure.