background image

User’s Guide

Keysight E5053A                                    

Microwave Downconverter

Summary of Contents for E5053A

Page 1: ...User s Guide Keysight E5053A Microwave Downconverter...

Page 2: ...uter software under the same terms by which the software is customarily provided to the public Accordingly Keysight provides the Software to U S government customers under its standard commercial lice...

Page 3: ...appropriate for the instrument being used refer to your instrument s Function Reference Electrostatic discharge ESD can damage the highly sensitive microcircuits in your instrument ESD damage is most...

Page 4: ...ent unless another person capable of rendering first aid and resuscitation is present Do NOT Substitute Parts or Modify the Instrument To avoid the danger of introducing additional hazards do not inst...

Page 5: ...facilities of other International Standards Organization members Exclusive Remedies The remedies provided herein are Buyer s sole and exclusive remedies Keysight Technologies shall not be liable for a...

Page 6: ...Keysight E5053A Microwave Downconverter Caution Safety Symbols For any assistance contact your nearest Keysight Technologies Sales and Service Office Addresses are provided at the back of this manual...

Page 7: ...t 15 Mounting handle kit Option 1CN 16 Mounting rackmount kit Option 1CM 17 Mounting rackmount handle kit Option 1CP 17 Power supply and fuse 18 Checking the power supply 18 Setting up the fuse 18 Che...

Page 8: ...rconnection Ports and Test Ports 31 Cleaning a Display Other than Interconnection Ports and Test Ports 31 Cautions Applicable to Requesting Repair Replacement Regular Calibration etc 32 Devices to be...

Page 9: ...ny of the following in the inspection contact you nearest Keysight Technologies sales office 1 If the shipping container or cushioning material is damaged or the cushioning material shows signs of unu...

Page 10: ...1 Option o Manual Option ABA 3 User s Guide E5053 900x0 1 o Handle kit Option 1CN 4 5063 9227 1 o Rackmount kit Option 1CM 5 5063 9214 1 E5053 61623 2 E5053 61624 2 o Rackmount handle kit Option 1CP 5...

Page 11: ...Keysight E5053A Microwave Downconverter 11 Installation Incoming inspection Figure 1 1 Accessories...

Page 12: ...nvironmental conditions Temperature 10 C to 40 C Temperature range for error correction 23 C 5 C 1 C deviation from the temperature when performing the error correction Humidity 20 to 80 at wet bulb t...

Page 13: ...rmation on ambient temperature to satisfy the specifications and measurement accuracy of the product refer to the Specifications and supplemental performance characteristics Chapter in the User s Guid...

Page 14: ...ing space to disconnect the power cable s plug As described in Cutting power supply on page 20 the disconnecting device the device to cut the supply of power of the E5053A is the plug of the power cab...

Page 15: ...o move transport it Option 1CN and how to mount it into a rack as part of a measurement system Option 1CM without handles Option 1CP with handles Option Name Keysight part number 1CN Handle kit 5063 9...

Page 16: ...low these steps to mount it referring to the Figure 1 4 Step 1 Remove the trim strips 1 stuck to both the sides of the front panel stuck to the frame Step 2 Mount the front handles 3 to both the sides...

Page 17: ...on Step 4 Mount the E5053A into the rack Mounting rackmount handle kit Option 1CP The rackmount handle kit is a kit that contains both the flanges for rackmount and the front handles for the E5053A Fo...

Page 18: ...t meets the following specifications UL CSA type Slo Blo 5x20 mm miniature fuse 3A 250V Keysight part number 2110 1017 Spare fuses are available from Keysight Technologies sales offices To check or re...

Page 19: ...from shock hazards Step 1 Check the power cable you use for damage Step 2 Connect the attached power cable between the power cable receptacle on the rear panel of the E5053A see Figure 1 5 on page 18...

Page 20: ...at the switch pushed in is pulled up Cutting power supply For the E5053A the disconnecting device the device to cut the power supply is the power cable s plug on the power outlet side or the E5053A si...

Page 21: ...of Product This chapter presents an overview of the E5053A microwave downconverter About This Product The Keysight E5053A is a microwave downconverter associated with the E5052B signal source analyzer...

Page 22: ...hannel 2 input output port When using an external mixer disconnect this port 3 IF LO channel 1 input output port When using an external mixer disconnect this port 4 RF channel 2 input output port Conn...

Page 23: ...1010 1 Do not apply a DC voltage greater than 0 V to the connection port In particular there is the risk of the capacitor remaining charged Connect the measurement sample DUT after the analyzer has be...

Page 24: ...cts female 2 External reference signal input connector channel 1 channel 2 Ref In A reference signal input connector in order to phase lock the E5053A measurement signal with an external frequency ref...

Page 25: ...onnector for outputting the internal frequency reference signal from the E5053A By connecting this output connector to the external reference signal input connector of another device the device can be...

Page 26: ...26 Keysight E5053A Microwave Downconverter Overview of Product Names and Functions of Parts 2...

Page 27: ...5053A Microwave Downconverter User s Guide 3 Connecting Devices to E5052B for Operation This chapter describes how to connect the E5052B signal source analyzer and the E5053A microwave downconverter f...

Page 28: ...cable supplied with the E5053A Keysight part number E5053 61621 E5053 61622 USB cable supplied with the E5053A Keysight part number 8121 0770 BNC m BNC m cable 61 cm supplied with the E5053A Keysight...

Page 29: ...el As shown in Figure 3 2 connect the E5052B and the rear panel of the E5053A with the USB cable BNC cable and BNC adapter Figure 3 2 Connecting E5052B and E5053A Rear Panel Do not connect disconnect...

Page 30: ...the Measurement Using the E5053A and a External Mixer chapter in the E5052B Signal Source Analyzer User s Guide If the E5052B is turned on first the E5053A cannot be recognized and the downconverter...

Page 31: ...onnectors free from stains and dust Do not touch the contact surface on the connectors Do not plug damaged or scratched connectors into the test ports Use compressed air for cleaning connectors Do not...

Page 32: ...calibration of the unit by our Service Center send only the E5053A main unit without any installed option you may have ordered Unless specifically instructed it is not necessary to send accessories a...

Page 33: ...ier than the current printing date of this manual Manual Changes To adapt this manual to your E5053A refer to Table A 1 Keysight Technologies uses a two part ten character serial number that is stampe...

Page 34: ...34 Keysight E5053A User s Guide Manual Changes Manual Changes...

Page 35: ...tion incoming inspection 9 Interconnection Ports Maintenance 31 Internal Reference Signal Output Connector 25 M manual changes 33 N names and functions of parts 22 O operating environment 12 P power s...

Page 36: ...Keysight E5053A User s Guide Index 36...

Page 37: ...This information is subject to change without notice Keysight Technologies 2005 2019 Edition 4 April 2019 E5053 90020 E5053 90020 www keysight com...

Reviews: