Controlling Multiple Instruments
3
For this configuration you have to start the M8070B software twice
with different command line options.
1 Start a command line window
2 Type in the following syntax:
> keysight.M8070B.exe /chassisid 1 /workspace
"InstrumentOne"
> keysight.M8070B.exe /chassisid 2 /workspace
"InstrumentTwo"
In this configuration only one PC is required to run two M8070B
instances simultaneously and both control their assigned instrument.
2 One PC with multiple instruments in a M9514A frame
on page -71 shows two instruments (shaded transparent
rectangles) hosted by a M9514A and controlled by a single PC only.
Figure 51
PC connected to AXIe frame 14 slot via PCIe
NOTE
A second or further instance of M8070B software is only required if there
is another BERT PG module in the second / further chassis. This means
that, if there are only AWG module(s) and/or M8046A modules within the
second / further chassis, then these are also recognized within the first