84
Keysight M8132A 640 GSa/s Digital Signal Processor User’s Guide
6
Remote Programming
<direction-list>: [BIDirection | PRODucer | CONSumer |
DUDirection] [,…]
Example
:ODI:PORT:CAP:DIR? -> “CONSumer, BIDirection”
:ODI:PORT<N>:CAPability:FCONtrols?
Query
:ODI:PORT1:CAPability:FCONtrols?
Parameters
None
Description
The query returns the list of flow control types supported by this port.
Return Format
[:ODI:PORT1:CAPability:FCONtrols]
<flow-control-list><NL>
<flow-control-list>: [NONE | IBANd | IBPChannel |
OOBWire | OOBBplane<M>] [,…]
<M> An integer, 0 - 13
Example
:ODI:PORT1:CAP:FCON? -> “NONE, IBANd”
:ODI:PORT<N>:CAPability:LANes?
Query
:ODI:PORT<N>:CAPability:LANes?
Parameters
None
Description
The query returns the number of lanes supported by this port.
Return Format
[:ODI:PORT<N>:CAPability:LANes] <lanes><NL>
Example
:ODI:PORT1:CAP:LAN? -> 12
:ODI:PORT<N>:CAPability:NAME?
Query
:ODI:PORT<N>:CAPability:NAME?
Parameters
None
Description
The query returns the name of the port.
Return Format
[:ODI:PORT<N>:CAPability:NAME] <name><NL>
Example
:ODI:PORT:CAP:NAME? -> “ODI1”