background image

1

2

Keysight PXIe Chassis Family Startup Guide

For the latest versions of the above documents, visit the Keysight website at 

www.

. The following documents are also available on this 

keysight.com/find/M9019A

website:

Keysight M9019A PXIe Chassis Data Sheet

Keysight M9022A/ M9023A/ M9024A PXIe system module Data Sheet

PC Tested Configuration with PXI/AXIe Chassis Technical Overview — This 

document lists the PCs that have been verified to work with the M9019A 
chassis.

Multiple PXIe and AXIe Chassis System Configuration Tool

To assist you in locating the documentation that will best meet your needs, the 
following table lists the recommended chassis documents by audience. Also listed 
are the key topics covered in each group of documents.

Product specifications, available accessories, firmware and software may change 
over time. Check the Keysight website at 

 for 

www.keysight.com/find/pxi-chassis

the latest updates to the product software, guides, help files and data sheets.

Audience

Recommended Documents

Key Topics

First-time 

users of

the PXIe 

chassis

PXIe Chassis Family Startup Guide 

M9019A Data Sheet

M9022A/ M9023A/ M9024A/ M9048B/ 
M9049A Data Sheet

PC Tested Configuration with PXIe/AXIe 
Chassis Technical Overview

Documentation for each module

SFP Help

Interactive Block diagram

Multiple PXIe and AXIe Chassis System 
Configuration Tool

- PXIe chassis architecture 

and

 

capabilities

- Selection of the host 

controller PC

- Connecting the chassis to a 

computer

 

and powering up 

the system

 

- Using Connection Expert 

and the soft

 

front panel (SFP) 

to verify chassis

 

operation

- Installing Keysight modules 

in the

 

chassis

- Using the SFP to configure 

the chassis

For more information on Multiple PXIe and AXIe Chassis System Configuration 
Tool, check the Keysight website at 

www.keysight.com/find/pxie-multichassis

.

Summary of Contents for M9019A PXIe

Page 1: ...Keysight PXIe Chassis Family Startup Guide M9019A...

Page 2: ......

Page 3: ...IS PROVIDED AS IS AND IS SUBJECT TO BEING CHANGED WITHOUT NOTICE IN FUTURE EDI TIONS FURTHER TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW KEYSIGHT DISCLAIMS ALL WAR RANTIES EITHER EXPRESS OR IMPL...

Page 4: ...erform proce dures involving cover or shield removal unless you are qualified to do so DO NOT operate damaged equipment Whenever it is possible that the safety protection features built into this prod...

Page 5: ...evice complies with the Canadian ICES 001 This symbol represents the time period during which no hazardous or toxic substance elements are expected to leak or deteriorate during normal use Forty years...

Page 6: ...controller in the chassis 19 Installing software on the host controller 20 Installing the Keysight IO Libraries Suite 21 Installing the PXIe chassis software 21 Installing the chassis software from M9...

Page 7: ...Keysight PXIe Chassis Family Startup Guide 7...

Page 8: ...power up the chassis and verify basic operation including the following The features and capabilities of PXIe chassis How a chassis system is shipped and what is included with the chassis itself Comp...

Page 9: ...slots in the chassis many computers are not capable of enumerating a sufficient number of PCIe slots to ensure that slots in an external chassis are enumerated Keysight provides the document PC Teste...

Page 10: ...GB s slot to slot Multi chassis power sequencing and front panel external trigger inputs outputs Specified up to 55 oC and 10 000 ft operating conditions The following image shows a front view of the...

Page 11: ...together provide a significant level of ESD protection Of the two only the table mat and wrist strap combination provides adequate ESD protection when used alone To ensure user safety the static safe...

Page 12: ...ware may change over time Check the Keysight website at for www keysight com find pxi chassis the latest updates to the product software guides help files and data sheets Audience Recommended Document...

Page 13: ...assis to Keysight for service Service Guide M9019A chassis shipment verification Verify that your chassis shipment contains the following items Keysight M9019A PXIe Chassis Power cord This document in...

Page 14: ...device It disconnects the mains circuits from the mains supply to the chassis before other parts of the chassis The front panel switch is only a standby switch and is not a LINE switch Alternatively a...

Page 15: ...GB available hard disk space includes 1GB available for Microsoft NET Framework 3 5 SP1 100 MB for Keysight IO Libraries Suite Video Support for DirectX 9 graphics with 128 MB graphics memory recommen...

Page 16: ...that air can enter through the bottom of the chassis Also ensure that there is at least 50 mm 2 inches of clearance on the sides front and rear of the chassis Removing and installing filler panels The...

Page 17: ...IOS must support enumeration of the PCIe slots in the chassis many computers are not capable of enumerating a sufficient number of PCIe slots to ensure that slots in an external chassis are enumerated...

Page 18: ...s Take care to ensure that the module is aligned perpendicularly to the chassis as you begin sliding it in Otherwise it is possible for components on the module or on adjacent modules to be damaged by...

Page 19: ...in the chassis An embedded controller such as the Keysight M9037A Embedded Controller is a small form factor Windows based PC that is designed to be installed in the system controller slot slot 1 of t...

Page 20: ...To do this the CD software can be read on a PC optical drive and then copied to the embedded controller over the network or by using a USB flash drive If the embedded controller is connected to the n...

Page 21: ...get the latest version go to www keysight com find iosuite Installing the PXIe chassis software The PXIe chassis software consist of the chassis soft front panel SFP and the IVI C IVI NET LabVIEW and...

Page 22: ...Support Click the Drivers Firmware Software tab Select Keysight PXIe Chassis Software Click the Download button Select the appropriate executable file Choose Run Using the SFP is described in Using t...

Page 23: ...tor switch Ensure that the AC supply line voltage is within the range of 100 120 VAC or 220 240 VAC and 50 60 Hz frequency If this product is not used as specified the protection provided by the equip...

Page 24: ...anel power push button is used to switch the chassis between ON and Standby hence this push button is known as the ON Standby push button Using this push button requires that a module is installed in...

Page 25: ...s that the chassis is turned off If you attempt to turn the chassis on but the Power LED remains off this can indicate several possible problems Indicates that the four main supply voltages 3 3V 5V 12...

Page 26: ...ting below the limit either the 1200 RPM factory default limit or if changed the user set limit If the fan speed condition causing the flashing to occur is no longer present the Fan LED will return to...

Page 27: ...the chassis If Windows can not find a driver for a device Windows will not be able to identify the device and therefore Connection Expert will not be able to display it If this occurs you will typical...

Page 28: ...chassis configuration as displayed by Connection Expert differs from your actual configuration click the button Rescan This should align the displayed configuration to the actual configuration Even w...

Page 29: ...the status of the chassis configuring chassis parameters is described in the Keysight PXIe Chassis Family User Guide Starting the SFP and selecting Hardware Mode or Simulation Mode The SFP runs in two...

Page 30: ...erefore the SFP can only be run in simulation mode To run in simulation mode select the Simulation Mode check box in the above image This displays M9019A in the Modules list Then click M9019A in the M...

Page 31: ...is unchecked by Allow Control default as shown below The unchecked box prevents any configuration change from being made In the which Keysight PXIe Chassis Family User Guide describes how to use the...

Page 32: ...or 3 3V alarm the factory default limits are plus and minus 10 around the nominal values Each of the other four voltage alarms has upper and lower voltage limits of 5 about the nominal voltage For exa...

Page 33: ...e instructions for this module are applicable to all modules installed in the chassis Installing the module software The PXIe chassis drivers that you installed in the Installing the PXIe chassis soft...

Page 34: ...to connect to the chassis on page 28 section and as described in your module documentation Bring up the soft front panel SFP for your module if available and verify that the SFP can interface correctl...

Page 35: ...8B PCIe host adapter single port x8 Gen 3 M9049A PCIe host adapter dual port 16 Gen 3 M9022A PXIe system module single port x8 Gen 3 M9023A PXIe high performance system module dual port x16 Gen 3 M902...

Page 36: ...This information is subject to change without notice Keysight Technologies 2016 Edition 1 July 2016 Printed In Malaysia M9019 90001 www keysight com...

Reviews: