Safety Information

The following general safety precau-

tions must be observed during all 

phases of operation of this instrument. 

Failure to comply with these precau-

tions or with specific warnings or oper-

ating instructions in the product 

manuals violates safety standards of 

design, manufacture, and intended use 

of the instrument. Keysight Technolo-

gies assumes no liability for the cus-

tomer's failure to comply with these 

requirements. 

General

Do not use this product in any manner not 

specified by the manufacturer. The protec-

tive features of this product must not be 

impaired if it is used in a manner specified in 

the operation instructions.

Before Applying Power

Verify that all safety precautions are taken. 

Make all connections to the unit before 

applying power. Note the external markings 

described under “Safety Symbols”.

Ground the Instrument

Keysight chassis’ are provided with a 

grounding-type power plug. The 

instrument chassis and cover must be 

connected to an electrical ground to 

minimize shock hazard. The ground pin 

must be firmly connected to an electri-

cal ground (safety ground) terminal at 

the power outlet. Any interruption of 

the protective (grounding) conductor 

or disconnection of the protective 

earth terminal will cause a potential 

shock hazard that could result in per-

sonal injury.

Do Not Operate in an Explosive 

Atmosphere

Do not operate the module/chassis in 

the presence of flammable gases or 

fumes.

Do Not Operate Near Flammable 

Liquids

Do not operate the module/chassis in 

the presence of flammable liquids or 

near containers of such liquids.

Cleaning

Clean the outside of the Keysight mod-

ule/chassis with a soft, lint-free, 

slightly dampened cloth. Do not use 

detergent or chemical solvents.

Do Not Remove Instrument Cover

Only qualified, service-trained person-

nel who are aware of the hazards 

involved should remove instrument 

covers. Always disconnect the power 

cable and any external circuits before 

removing the instrument cover.

Keep away from live circuits

Operating personnel must not remove 

equipment covers or shields. Proce-

dures involving the removal of covers 

and shields are for use by service-

trained personnel only. Under certain 

conditions, dangerous voltages may 

exist even with the equipment 

switched off. To avoid dangerous elec-

trical shock, DO NOT perform proce-

dures involving cover or shield removal 

unless you are qualified to do so.

DO NOT operate damaged 

equipment

Whenever it is possible that the safety 

protection features built into this prod-

uct have been impaired, either through 

physical damage, excessive moisture, 

or any other reason, REMOVE POWER 

and do not use the product until safe 

operation can be verified by service-

trained personnel. If necessary, return 

the product to an Keysight Technolo-

gies Sales and Service Office for ser-

vice and repair to ensure the safety 

features are maintained.

DO NOT block the primary 

disconnect

The primary disconnect device is the 

appliance connector/power cord when 

a chassis used by itself, but when 

installed into a rack or system the dis-

connect may be impaired and must be 

considered part of the installation.

Do Not Modify the Instrument

Do not install substitute parts or per-

form any unauthorized modification to 

the product. Return the product to an 

Keysight Sales and Service Office to 

ensure that safety features are main-

tained.

In Case of Damage

Instruments that appear damaged or 

defective should be made inoperative 

and secured against unintended oper-

ation until they can be repaired by 

qualified service personnel.

Do NOT block vents and fan exhaust: 

To ensure adequate cooling and venti-

lation, leave a gap of at least 50mm 

(2") around vent holes on both sides of 

the chassis. 
Do NOT operate with empty slots: To 

ensure proper cooling and avoid dam-

aging equipment, fill each empty slot 

with an AXIe filler panel module.
Do NOT stack free-standing chassis: 

Stacked chassis should be rack-

mounted. 
All modules are grounded through the 

chassis: During installation, tighten 

each module's retaining screws to 

secure the module to the chassis and 

to make the ground connection.

Operator is responsible to maintain 

safe operating conditions. To ensure 

safe operating conditions, modules 

should not be operated beyond the full 

temperature range specified in the 

Environmental and physical specifica-

tion. Exceeding safe operating condi-

tions can result in shorter lifespan, 

improper module performance and 

user safety issues. When the modules 

are in use and operation within the 

specified full temperature range is not 

maintained, module surface tempera-

tures may exceed safe handling condi-

tions which can cause discomfort or 

burns if touched. In the event of a 

module exceeding the full temperature 

range, always allow the module to cool 

before touching or removing modules 

from the chassis.

iv

Summary of Contents for M9019A PXIe

Page 1: ...Keysight PXIe Chassis Family Startup Guide M9019A...

Page 2: ......

Page 3: ...IS PROVIDED AS IS AND IS SUBJECT TO BEING CHANGED WITHOUT NOTICE IN FUTURE EDI TIONS FURTHER TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW KEYSIGHT DISCLAIMS ALL WAR RANTIES EITHER EXPRESS OR IMPL...

Page 4: ...erform proce dures involving cover or shield removal unless you are qualified to do so DO NOT operate damaged equipment Whenever it is possible that the safety protection features built into this prod...

Page 5: ...evice complies with the Canadian ICES 001 This symbol represents the time period during which no hazardous or toxic substance elements are expected to leak or deteriorate during normal use Forty years...

Page 6: ...controller in the chassis 19 Installing software on the host controller 20 Installing the Keysight IO Libraries Suite 21 Installing the PXIe chassis software 21 Installing the chassis software from M9...

Page 7: ...Keysight PXIe Chassis Family Startup Guide 7...

Page 8: ...power up the chassis and verify basic operation including the following The features and capabilities of PXIe chassis How a chassis system is shipped and what is included with the chassis itself Comp...

Page 9: ...slots in the chassis many computers are not capable of enumerating a sufficient number of PCIe slots to ensure that slots in an external chassis are enumerated Keysight provides the document PC Teste...

Page 10: ...GB s slot to slot Multi chassis power sequencing and front panel external trigger inputs outputs Specified up to 55 oC and 10 000 ft operating conditions The following image shows a front view of the...

Page 11: ...together provide a significant level of ESD protection Of the two only the table mat and wrist strap combination provides adequate ESD protection when used alone To ensure user safety the static safe...

Page 12: ...ware may change over time Check the Keysight website at for www keysight com find pxi chassis the latest updates to the product software guides help files and data sheets Audience Recommended Document...

Page 13: ...assis to Keysight for service Service Guide M9019A chassis shipment verification Verify that your chassis shipment contains the following items Keysight M9019A PXIe Chassis Power cord This document in...

Page 14: ...device It disconnects the mains circuits from the mains supply to the chassis before other parts of the chassis The front panel switch is only a standby switch and is not a LINE switch Alternatively a...

Page 15: ...GB available hard disk space includes 1GB available for Microsoft NET Framework 3 5 SP1 100 MB for Keysight IO Libraries Suite Video Support for DirectX 9 graphics with 128 MB graphics memory recommen...

Page 16: ...that air can enter through the bottom of the chassis Also ensure that there is at least 50 mm 2 inches of clearance on the sides front and rear of the chassis Removing and installing filler panels The...

Page 17: ...IOS must support enumeration of the PCIe slots in the chassis many computers are not capable of enumerating a sufficient number of PCIe slots to ensure that slots in an external chassis are enumerated...

Page 18: ...s Take care to ensure that the module is aligned perpendicularly to the chassis as you begin sliding it in Otherwise it is possible for components on the module or on adjacent modules to be damaged by...

Page 19: ...in the chassis An embedded controller such as the Keysight M9037A Embedded Controller is a small form factor Windows based PC that is designed to be installed in the system controller slot slot 1 of t...

Page 20: ...To do this the CD software can be read on a PC optical drive and then copied to the embedded controller over the network or by using a USB flash drive If the embedded controller is connected to the n...

Page 21: ...get the latest version go to www keysight com find iosuite Installing the PXIe chassis software The PXIe chassis software consist of the chassis soft front panel SFP and the IVI C IVI NET LabVIEW and...

Page 22: ...Support Click the Drivers Firmware Software tab Select Keysight PXIe Chassis Software Click the Download button Select the appropriate executable file Choose Run Using the SFP is described in Using t...

Page 23: ...tor switch Ensure that the AC supply line voltage is within the range of 100 120 VAC or 220 240 VAC and 50 60 Hz frequency If this product is not used as specified the protection provided by the equip...

Page 24: ...anel power push button is used to switch the chassis between ON and Standby hence this push button is known as the ON Standby push button Using this push button requires that a module is installed in...

Page 25: ...s that the chassis is turned off If you attempt to turn the chassis on but the Power LED remains off this can indicate several possible problems Indicates that the four main supply voltages 3 3V 5V 12...

Page 26: ...ting below the limit either the 1200 RPM factory default limit or if changed the user set limit If the fan speed condition causing the flashing to occur is no longer present the Fan LED will return to...

Page 27: ...the chassis If Windows can not find a driver for a device Windows will not be able to identify the device and therefore Connection Expert will not be able to display it If this occurs you will typical...

Page 28: ...chassis configuration as displayed by Connection Expert differs from your actual configuration click the button Rescan This should align the displayed configuration to the actual configuration Even w...

Page 29: ...the status of the chassis configuring chassis parameters is described in the Keysight PXIe Chassis Family User Guide Starting the SFP and selecting Hardware Mode or Simulation Mode The SFP runs in two...

Page 30: ...erefore the SFP can only be run in simulation mode To run in simulation mode select the Simulation Mode check box in the above image This displays M9019A in the Modules list Then click M9019A in the M...

Page 31: ...is unchecked by Allow Control default as shown below The unchecked box prevents any configuration change from being made In the which Keysight PXIe Chassis Family User Guide describes how to use the...

Page 32: ...or 3 3V alarm the factory default limits are plus and minus 10 around the nominal values Each of the other four voltage alarms has upper and lower voltage limits of 5 about the nominal voltage For exa...

Page 33: ...e instructions for this module are applicable to all modules installed in the chassis Installing the module software The PXIe chassis drivers that you installed in the Installing the PXIe chassis soft...

Page 34: ...to connect to the chassis on page 28 section and as described in your module documentation Bring up the soft front panel SFP for your module if available and verify that the SFP can interface correctl...

Page 35: ...8B PCIe host adapter single port x8 Gen 3 M9049A PCIe host adapter dual port 16 Gen 3 M9022A PXIe system module single port x8 Gen 3 M9023A PXIe high performance system module dual port x16 Gen 3 M902...

Page 36: ...This information is subject to change without notice Keysight Technologies 2016 Edition 1 July 2016 Printed In Malaysia M9019 90001 www keysight com...

Reviews: