background image

Keysight 16117C 

Low Noise Test Lead

Operation and 

Service Manual

Summary of Contents for 16117C

Page 1: ...Keysight 16117C Low Noise Test Lead Operation and Service Manual...

Page 2: ......

Page 3: ......

Page 4: ...ing charges duties and taxes for products returned to Agilent Technologies from another country Agilent Technologies warrants that its software and rmware designed by Agilent Technologies for use with...

Page 5: ...mages whether based on contract tort or any other legal theory Assistance Product maintenance agreements and other customer assistance agreements are available for Agilent Technologies products If you...

Page 6: ...ns and updates which are incorporated at reprint do not cause the date to change The manual part number changes when extensive technical changes are incorporated December 1991 First Edition February 1...

Page 7: ...placement and internal adjustments must be made only by quali ed maintenance personnel Do not replace components with the power cable connected Under certain conditions dangerous voltages may exist ev...

Page 8: ...ion sign denotes a hazard It calls attention to a procedure practice condition or the like which if not correctly performed or adhered to could result in damage to or destruction of part or all of the...

Page 9: ...Use Introduction 2 1 Initial Inspection 2 1 Ambient Environmental Considerations 2 3 Operating and Storage 2 3 Connecting the Adapter for Use 2 3 Packaging the Adapter 2 4 3 Operation Introduction 3 1...

Page 10: ...1 3 2 Floating DUT Measurement Con guration 3 2 3 3 Interlock cable Assignment Wiring Side View 3 3 3 4 Example Con guration of Custom Test Fixture 3 5 Tables 1 1 Furnished Accessories 1 1 2 1 Content...

Page 11: ...the 16117C turn to Chapter 3 To order replaceable parts for the 16117C turn to Replaceable Parts in Chapter 4 Product Description The 16117C has been designed to operate speci cally with the 4339B Hig...

Page 12: ...ts against which the 16117C is tested When shipped from the factory the 16117C meets the speci cations listed in this section Applicable Test Voltage 1000 V maximum Applicable Test Current1 10 mA maxi...

Page 13: ...hould be in perfect electrical condition Verify this by carefully performing an incoming inspection to check the adapter for signs of physical damage and missing contents If any discrepancy is found n...

Page 14: ...ilent Part Number Quantity 1 Low Noise Test Lead 16117C 1 2 BNC Female Connector 1250 2317 1 3 Triaxial Female Connector 1250 2228 1 4 Operation and Service Manual1 16117 90041 1 1 Operation and Servi...

Page 15: ...9B connection with 16117C has two con gurations oating and grounded DUT measurement con gurations The connections are di erent for each con guration The connections are as shown in Figure 2 2 and Figu...

Page 16: ...ginal factory packaging materials Alteratively comparable packaging materials may be used Wrap the adapter in heavy paper and pack in anti static plastic packing material Use su cient shock absorbing...

Page 17: ...h voltage BNC connector and is not compatible with standard BNC connectors 2 Triaxial cable The measured signal is carried on the center conductor of this connector 3 Interlock cable This connector en...

Page 18: ...with the 16117C Figure 3 2 Floating DUT Measurement Con guration The BNC connector provides source voltage up to 1000 V A triaxial connector is used for the measured signal path The triaxial connector...

Page 19: ...erlock cable has six lines The 4339B changes some settings Voltage Output Current Limit and Resistivity Mode depending on the interlock status Table 3 1 describes the role of each line Table 3 1 Pin A...

Page 20: ...Limitation GND GND Open 16008B No Limitation GND Open GND 16117B Current Limit 0 5 mA GND Open Open 04339 65005 100 V maximum Current Limit 1 mA Open GND GND Not Applicable n a Not Used No Voltage out...

Page 21: ...lose of this cover Figure 3 4 Example Con guration of Custom Test Fixture Center conductor of BNC connector and center conductor of triaxial connector is connected to contact of DUT A source voltage o...

Page 22: ...d that operator can measure safely To keep safety condition you must execute following checking procedure periodically This procedure assumes your xture has top cover interlocing source voltage output...

Page 23: ...Holder with Nuts 1 16117 87103 2 Warning Label Red on BNC and Triaxial cable 16117 87104 1 Label Yellow on Interlock cable 16117 61604 1 Cable Assembly Triaxial 2 16117 61605 1 Cable Assembly BNC 2 1...

Page 24: ......

Page 25: ...This information is subject to change without notice Keysight Technologies 2014 Edition 6 November 2014 16117 90041 16117 90041 www keysight com...

Reviews: