Base Matrix Configuration
2
Keysight 34934A User’s Guide
67
34934A Module D-Sub Connectors: 4x32 Wiring
When wiring directly to the 34934A’s D-Sub connectors, you
must
make the
following connections—in addition to row and column connections—to configure
the 4x32 matrix (matrices):
Module ID:
The open pins listed below allow the 34980A mainframe to
recognize the 4x32 matrix configuration.
Leave Open: Pin 39 on Bank 1 (ID
bit
2)
Leave Open: Pin 39 on Bank 2 (ID
bit
1)
Leave Open: Pin 59 on Bank 2 (ID
bit
0)
Safety Interlock Continuity:
The connections listed below provide for safety
interlock continuity.
Short: Pin 59 (IL3) to Pin 77 (IL4) on Bank 1
Short: Pin 40 (IL2) to Pin 61 (IL1) on Bank 2
R4H
3
C4H
17
C12H
33
C20H
57
C28H
65
R4L
4
C4L
18
C12L
34
C20L
58
C28L
66
C5H
7
C13H
35
C21H
43
C29H
67
C5L
8
C13L
36
C21L
44
C29L
68
C6H
11
C14H
37
C22H
45
C30H
69
C6L
12
C14L
38
C22L
46
C30L
70
C7H
15
C15H
23
C23H
49
C31H
71
C7L
16
C15L
24
C23L
50
C31L
72
C8H
19
C16H
29
C24H
51
C32H
75
C8L
20
C16L
30
C24L
52
C32L
76
Description Pin
Description Pin
Description Pin
Description Pin
Description Pin
Description Pin
NOTE
If you use the 34934C-001 Configuration Block—in conjunction with the 34934A
module—to make wiring connections, the additional
Module ID
connections are
not required
. Those connections are made within the hardware of the
configuration block. You would need only make the
Safety Interlock Continuity
connections.