From the remote interface:
To select the trigger input function:
DIG:PIN1:FUNC TINP
To select the pin polarity:
DIG:PIN1:POL POS
DIG:PIN1:POL NEG
Trigger output
Any of the Digital Control pins can be programmed to function as a trigger output. All pins are referenced to the
Signal Common pin.
When configured as a trigger output, the designated trigger pin will generate a 10-microsecond trigger pulse in
response to a trigger event. The polarity setting can be either positive-going (rising edge) or negative-going (falling
edge) when referenced to common.
Trigger out signals can be generated when configuring the voltage and current in the Output LIST. If you check the
BOST and EOST boxes when configuring the Output LIST, an output trigger signal will be generated on the
configured digital pin at the start and end of the voltage and current step.
From the front panel:
1. Press
Utilities
>
I/O Config
>
Digital IO
to access the Digital I/O window.
2. Select the pin you wish to configure. For example, press
Pin 1
to configure Pin 1.
3. Press
Function
and select
Trigger Out
. Select and program the remaining pins in the same manner. Press
Back
to
return to previous page.
4. Configure the polarity for each of the pin. Press
Polarity Pos
to select Positive and
Polarity Neg
to select
Negative. Select and program the remaining pins in the same manner.
From the remote interface:
To select the trigger output function:
DIG:PIN1:FUNC TOUT
To select the pin polarity:
DIG:PIN1:POL POS
DIG:PIN1:POL NEG
Output couple controls
This function lets you connect multiple Keysight E36300 Series power supplies together and synchronize the output
on/off sequence across units. Each power supply that will be synchronized must have at least one coupled output.
72