Operating the Power Supply Locally
3
Series N5700 User’s Guide
47
•
Set the programming resistors to the desired resistance and turn
the power supply on. Adjust the resistors to change the power
supply output.
The analog control circuits let you set the output voltage and current
limit up to 5% over the model-rated maximum value. The power supply
will operate within the extended range, however it is not recommended
to operate the power supply over its voltage and current rating, and
performance in this region is not guaranteed.
SW1 switch 3
Voltage Programming
(J1 pin 9)
Current programming
(J1 pin 10)
Down (default)
0 – 5 kΩ
0 – 5 kΩ
Up
0 – 10 kΩ
0 – 10 kΩ
External Monitoring of Output Voltage and Current
The J1 connector also provides analog signals for monitoring the output
voltage and current. Selection of the voltage range between 0 – 5 V or 0 –
10 V is made by SW1 setup switch 4. The monitoring signals represent 0
to 100% of the power supply output voltage and current rating. The
monitor outputs have a 500 Ω series output resistance. Make sure that
the sensing circuit has an input resistance greater than 500 kΩ or the
accuracy will be reduced.
SW1 switch 4
Voltage
range
J1 signal
connection
Signal function
Down (default)
0 – 5 V
J1 pin 11
Voltage Monitor
J1 pin 24
Current Monitor
Up
0 – 10 V
J1 pin 11
Voltage Monitor
J1 pin 24
Current Monitor
J1 pin 12 is the signal common for J1 pins 11 and 24.