background image

How to designate Telephone Numbers to TRIG 1 and TRIG 2 

– Section 6 : 

 

Quick guide: Press 1 2 3 4 > PROGRAM > 6 > ENTER > X > ENTER > N > ENTER 
 
1) Key in the four digit user PASSWORD code (factory default 1234) 
2) Press PROGRAM > 6 > ENTER.  
3) 

Press 1 (for TRIG 1), or press 2 (for TRIG 2). Press ENTER 

4) You will now see numbers 123456789  illuminated.  This indicates that all 9 telephone numbers (or as many as 
have been programmed into the dialer) will be called on that trigger. 
5) Press 1 - 9 to de-select 

that phone number from being dialed.  You will now see a blank “-“ where  that number 

was previously.  Press ENTER to save the setting. 
5) Repeat the process until you have designated all the numbers to each trigger. Remember that you can 
designate all 9 numbers to each trigger or only some to one and some to the other.  

 

 

IMPORTANT 

: The numbers shown on the LCD display are the phone numbers assigned to that trigger. Pressing 

buttons 1 to 9 will toggle the numbers on/off on 1-9 respectively.  If a number is not shown, then it means that it 
will not be called. 
 
Example:  123

—67-9 means that telephone numbers 1,2,3,6,7 and 9 only will be dialed for that particular trigger.   

 
 

                     
                                Other Programming Sections

 

 

 

 
 

How to Program the Auto Dialer to give a local Audible Alarm as well as sending a voice message 

– 

Section 1:  

(Default setting is alarm OFF)

 

 
Quick guide: Press1 2 3 4 > PROGRAM > 1 > ENTER > 1 > ENTER 
 
1) Key in the four digit user <PASSWORD> code. (Factory default 1234) 
2) Press PROGRAM > 1 > ENTER > 1 > ENTER 
(Please note 0 = without Audible Alarm, 1 = with Audible Alarm)

 

               

 

 

How to Set the Time the Audible local Alarm will sound on activation 

– Section 2  : 

(Default time is 3 mins) 

 
Quick guide: Press 1 2 3 4 > PROGRAM > 2 > ENTER > Time > ENTER (Alarm sound time is from 1M-99M.) 
 
1) Key in the four digit user <PASSWORD> code. (Factory default 1234). 
2) Press PROGRAM > 2 > ENTER > Time > ENTER. 
TIME = <1> = 1 min, <99> = 99 min (max TIME 99 min). We recommend you do not exceed a 20 min 
Alarm duration.

 

 

 

 

How to set Trigger Delay Delay times: (Default is 0 seconds - instant) 

– Section 4 

 

Set trigger delay time between 0, 30 and 60 seconds:  As a false alarm prevention feature, this is the delay 
between a trigger being activated and when the dialer starts to dial out.  Default setting is 0 secs. 
 
Quick guide: Press 1 2 3 4 > PROGRAM > 4 > ENTER > N > ENTER 
 
1. Key in the four digit user Password code (factory default 1234) 
2. Press PROGRAM > 4 > ENTER > N > ENTER. 
(Note: N=0, instant; N=3, 30 sec; N=6, 60 sec.)

 

 

 

 

 

 

Summary of Contents for AD-01

Page 1: ...rigger Built in memory for telephone numbers and programmed settings Contents 1 x Auto Dialer 1 x Telephone cable 1 x Fixing kit and Installation Programming guide Preparation MIC AutoDialer Tools req...

Page 2: ...olarity Usually back up power would be supplied from the alarm panel battery to which the dialer is connected 10 The auto Dialer will beep once 11 Replace the battery compartment cover 12 Connect the...

Page 3: ...ween the Dialer being turned on armed and becoming active Default No delay 6 Assign the 9 dial out Tel no s to trigger 1 and or 2 Default All Tel no s assigned to both trigger 1 2 7 Select an Audible...

Page 4: ...will change to acc How to Program Phone Numbers Section 3 You can enter a maximum of nine telephone numbers for the triggers each number can be a maximum of 32 digits Quick guide Press 1 2 3 4 PROGRAM...

Page 5: ...7 and 9 only will be dialed for that particular trigger Other Programming Sections How to Program the Auto Dialer to give a local Audible Alarm as well as sending a voice message Section 1 Default set...

Page 6: ...display 3 The triggers will become active after the delay time you have set has expired Default set at 0 seconds instant How to Turn Dialer OFF or to stop it dialing out after it has been triggered Q...

Page 7: ...ng on the Dialer s LCD display and it is not dialing out A Check the following carefully i Does the Dialer have a 12V supply either from the panel or via a 500ma 12V mains adaptor ii Have you made the...

Page 8: ...e number again and press Enter to exit Do NOT press ESC to exit as this will delete that number iii Have you de selected a number to be dialed out in sequence for that trigger by mistake Go to Program...