5
5
CONTROL PADS ON THE DEHUMIDIFIER
Other features
Bucket Full Light
Glows when the bucket is ready to be
emptied, or when the bucket is removed
or not replaced in the proper position.
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
Auto Defrost
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart
opertation in the first 3 minutes. This is to protect
the unit. Operation will automatically start after
3 minutes.
Setting the Timer
When the unit is on, first press the Timer
button, the Timer Off indicator light
illuminates. It indicates the Auto Stop
program is initiated. Press it again the
Time On indecator light illuminates.It
indicates the Auto Start is initiated.
Press or hold the UP or DOWN pad to
change the Auto time by 0.5 hour incre-
ments, up to 10 hours, then at 1 hour
increments up to 24 hours. The control
will count down the time remaining until
start.
The selected time will register in 5 seconds
and the system will automatically revert
back to display the previous humidity
setting.
When the Auto start & Auto stop times are
set, within the same program sequence,
TIMER ON OFF indicator lights illuminate
identifying both ON and OFF times are
now programmed.
Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel
the Auto Start/Stop function.
When LED display window displays the
code of P2, the Auto Start/Stop function
will also be cancelled.
When the unit is off, first press the Timer
button, the TIMER ON indicator light
illuminates. It indicates the Auto Start
program is initiated. Press it again the
Time Off indecator light illuminates.It
indicates the Auto Stop is initiated.
Check filter feature
The system starts to count the time once the fan
motor operates. The check filter feature can be
only activated when the accumulated operation
time achieves 250 hours or more. The Reset
light(Clean filter indicator light) flashes at one time
per second, after finishing clean the air filter, press
the Filter pad and the Reset light(Clean filter indicator
light) goes off.
10
10
Display
Shows the set % humidity level from 35% to 85% or auto
start/stop time (0~24) while setting, then shows the actual
(
5% accuracy) room % humidity level in a range of 30%
RH(Relative Humidity) to 90%RH(Relative Humidity).
Error Codes and Protection Code:
AS
- Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
ES
- Temperature sensor error-- Unplug the unit and plug it
back in. If error repeats, call for service.
P2
- Bucket is full or bucket is not in right position-- Empty
the bucket and replace it in the right position.
E1
- Unit malfunction-- Unplug the unit and plug it back in.
If error repeats, call for service.
Auto Shut Off
The dehumidifier shuts off after 30 seconds when
the bucket is full, or when the bucket is removed
or not replaced in the proper position.When the
setting humidity is reached, the unit will be shut
off automatically. For some models,the fan motor
will continue operating.
Auto-Restart
If the unit breaks off unexpectedly due to the power cut,
it will restart with the previous function setting automa-
tically when the power resumes.
EC
- Unit malfuction--
for
Please make sure whether the
enviroment temperature is suitable for the stated
temperature in the manual or not.If not,please operate
the unit under the stated temperature.If the enviroment
temperature is suitable for the stated temperature,please
call
service.