„Installation and operation manual“
7
Note
Safe distance between the internal side of the chimney and combustible elements is at
least 16 cm in case of a brick chimney. In case of steel chimneys, the information is
specified by the manufacturer (X).
Insulated
steel chimney
Combustible
elements
X
Brick
chimney
160
Combustible
elements
Figure 2. Safe distance of the chimney from combustible elements (dimensions in mm).
Safe distance for conducting the connecting pipe (combustion gas pipe) through a
combustible wall is at least 20 cm.
Figure 3. Method of conducting the combustion gas pipe through a combustible wall
(dimensions in mm).
2
0
0
2
0
0
200
Ściana palna
Rura spalinowa
Wypełnienie
(lekki beton lub wełna)
Kryza
z blachy stalowej
Filling (lightweight
concrete or wool)
Combustible wall
Combustion gas pipe
Steel sheet cap